Table 3. Statistical analysis of the evaluation of secondary measures.

Intra-class correlation coefficient (ICC) regarding the inter-rater reliability (ICC 2,6) and the intrarater reliability (ICC 3,6) according to the Shrout and Fleiss convention. Additionally the Variance of Components Analysis which allows for covariate effects is displayed including the 95% confidence interval for all primary measurements.

ICC(2,6) ICC(3,6) Variance Component Analysis
Parameter inter-rater
reliability
intra-rater
reliability
Intraclass
Correlation
ICC 95%
Confidence Interval
TCBF 0.998 0.998 0.979 0.967 0.990
JVF 0.992 0.995 0.942 0.926 0.959
ICVC 0.978 0.979 0.845 0.811 0.879
PG 0.999 0.999 0.989 0.984 0.993
ICCI 0.991 0.993 0.939 0.921 0.958
ICP 0.991 0.992 0.920 0.895 0.944