Skip to main content
. 2013 Apr 30;13:60. doi: 10.1186/1472-6920-13-60

Table 2.

Procedural checklist used by the video raters to evaluate performance

Action
Correct
Minor technical error
Major technical error
Breaches in aseptic technique
Preparation of materials (26 Points):        
Sterile gloves
 
 
 
 
Sterile gown
 
 
 
 
Cap
 
 
 
 
Mask
 
 
 
 
Disinfecting agent
 
 
 
 
Sterile gauze
 
 
 
 
Sterile compresses
 
 
 
 
Local anesthetic
 
 
 
 
3ml Syringe (for the anesthetic)
 
 
 
 
Needle (for the anesthetic)
 
 
 
 
Sterile drape
 
 
 
 
Sterile fenestrated drape
 
 
 
 
10 ml Syringe
 
 
 
 
Distilled water (to simulate NaCl 0.9%)
 
 
 
 
TLC
 
 
 
 
Seldinger needle
 
 
 
 
Guide wire
 
 
 
 
Dilator
 
 
 
 
Scalpel
 
 
 
 
3-way ports
 
 
 
 
Blood gas syringe
 
 
 
 
TLC holder/ clip
 
 
 
 
Suture thread
 
 
 
 
Needle driver
 
 
 
 
Adhesive bandage
 
 
 
 
Sharps container
 
 
 
 
Patient preparation (6 Points):
 
 
 
 
Sterile use of ultrasound equipment, if applied to find the vein
 
 
 
 
Hand washing/ sanitizing
 
 
 
 
All of the following are worn: sterile gloves and gown, mask, cap
 
 
 
 
Disinfection of the injection site
 
 
 
 
Fenestrated drape is applied to injection site
 
 
 
 
Injection of the local anesthetic (must aspirate before injection!)
 
 
 
 
Central line insertion (19 Points):
 
 
 
 
Both 10 mL syringes are filled with NaCl
 
 
 
 
All 3 lumina of the catheter are flushed with NaCl
 
 
 
 
All ports are blocked after the flush
 
 
 
 
Repeat disinfection of the injection site (assistant)
 
 
 
 
Insertion of Seldinger needle (30° angle)
 
 
 
 
Patient is asked if he can still feel the needle
 
 
 
 
The needle is inserted until the vein is punctured and blood can be drawn
 
 
 
 
A sample for blood gas analysis is drawn
 
 
 
 
Blood gas syringe is transferred to assistant
 
 
 
 
Insertion of the guide wire
 
 
 
 
Removal of the needle (the guide wire is secured in place)
 
 
 
 
Skin incision along the guide wire
 
 
 
 
Insertion of the dilator over the guide wire
 
 
 
 
Insertion of the catheter over the guide wire
 
 
 
 
The catheter is inserted through the skin only after the guide wire is secured
 
 
 
 
Removal of the guide wire (the catheter is secured in place)
 
 
 
 
Safe disposal of the guide wire (double knot/ sharps container)
 
 
 
 
Blood is drawn from all 3 lumina
 
 
 
 
All 3 lumina are flushed with NaCl
 
 
 
 
Securing the catheter and clean-up (4 Points):
 
 
 
 
TCL clip is attached to the catheter
 
 
 
 
TLC clip is sutured in place
 
 
 
 
The site of insertion is covered with an adhesive bandage
 
 
 
 
All needles and the scalpel are safely disposed of (sharps container) and the work station is left clean
 
 
 
 
Sum (max. 55 Points)
 
 
 
 
Miscellaneous:
 
Duration of the procedure
 
Number of misunderstandings (Physician-Assistant)
 
Number of questions from the assistants