Published in final edited form as: Comput Struct. 2012 Dec 27;122:78–87. doi: 10.1016/j.compstruc.2012.11.016

Table 2.

Summary of RV ejection fractions from 6 active band models (ABM) compared with the corresponding passive band model. Zero-stress end of systole band length for the passive band model was 4.18 cm. The zero-stress end of systole band length for the active band models with 10%, 15% and 20% active contraction were 3.76, 3.55, and 3.34 cm, respectively. Parameter for band material: c1=900 kPa, D1=0 kPa, D2=0.

Models Active Band Contraction (ABC) RVESV (ml) RVEDV (ml) RVEF
Models with Patch and Scar
FSI, No Band N/A 252.8 402.3 37.16%
FSI PBM 1 Passive 246.9 372.6 33.74%
FSI ABM1 ABC=10% 246.8 392.5 37.12%
FSI ABM2 ABC =15% 238.5 392.1 39.17%
FSI ABM3 ABC =20% 234.6 388.3 39.58%
Models with Patch and Scar Replaced by Normal Tissue
FSI ABM4 ABC=10% 247.5 407.8 39.30%
FSI ABM5 ABC =15% 239.2 403.6 40.73%
FSI ABM6 ABC =20% 235.0 401.5 41.47%