Table 3.

Comparison of V6 Levels in House Dust and Car Dust with Other FRs (commonly used in polyurethane foam) Detected in Other Studies in the US

House dust (ng/g) Car dust (ng/g)

Range GM Sampling Year Range GM Sampling Year
TPP < 150 – 1,798,00023 7360 2006 NAa NA NA
TCEP 330 – 110,00025 2700b 2011 < 20 – 50,120 (This study) 1,466 2009
TCPP < 140 – 5,49023 572 2006 NA NA NA
TDCPP < 90 – 56,09023 1890 2006 < 30 – 326,00026 12,500 2009

PentaBDEc 141 – 61,30027 2170 2009 151– 137,35024 1,779 NA
110 – 44,30027 2,610 2009
TBB < 450 – 75,00023 840 2006 NA NA NA
TBPH < 300 – 47,11023 650 2006 NA NA NA
“V6” < 5 – 1,117 (This study) 12b 2009 < 5 – 6,160 (This study) 103 2009
a

NA indicates not available.

b

Median was used.

c

PentaBDE is Sum of BDE 28/33, 47, 99, 100, and 153.

d

< LOQ indicates below limit of quantification.