Skip to main content
. 2012 Nov 27;54(3):532–545. doi: 10.1093/jrr/rrs111

Table 2.

Acceptance criteria for Organs-At-Risk (OARs)

OARs Specification Reference
Brainstem Dmax < 54 Gy RTOG
PRV of brainstem 1% vol < 60 Gy (preferable: 54 Gy vol <5%) RTOG
Spinal cord Dmax < 45 Gy RTOG
PRV of spinal cord 1% vol < 50Gy (preferable: 45 Gy vol <3%) RTOG
Chiasm Dmax < 54 Gy PWH
Lt and Rt optic nerve Dmax < 54 Gy PWH
Lt and Rt eyeball Dmax < 54 Gy (RTOG < 50 Gy) PWH
Lt and Rt lens Dmax < 10 Gy (RTOG < 25 Gy) PWH
Lt and Rt temporal lobe (TML) Dmax < 72 Gy or <4 cm3 vol > 60 Gy PWH
Lt and Rt parotid gland Dmean < 26 Gy or 50% vol < 30 Gy RTOG
Combined parotid glands >20 cm3 vol received < 20 Gy RTOG
Lt and Rt VIIIn and cochlea <5% vol > 55 Gy or Dmean < 50 Gy RTOG
Lt and Rt brachial plexus Dmax < 66 Gy RTOG
Laryngo-pharynx Dmean < 45 Gy RTOG
Lt and Rt TMJ Dmax < 70 Gy or <1 cm3 vol > 75 Gy RTOG
Oral cavity/trachea–oesophagus Dmean < 40 Gy RTOG
Unspecified tissues outside target: Posterior Brain, Posterior Neck <5% vol > 70 Gy or <1%/1cm3 vol > 70 Gy RTOG

Dmax = Maximum Dose, Dmean = Mean dose, PRV = Planning Organ-at-Risk Volume, VIIIn = Auditory nerve, TMJs = tempero-mandibular joints, RTOG = Radiation Therapy Oncology Group, PWH = Prince of Wales Hospital.