Skip to main content
. 2013 May 6;8:1795–1808. doi: 10.2147/IJN.S43555

Table 1.

Comparison of different methods (n = 3)

Method EE (%) LD (%) Particle size PDI
Dialysis method 70.21 ± 0.25 12.34 ± 1.23 200.3 ± 5.6 0.167 ± 0.127
Solvent evaporation method 75.34 ± 0.28 13.15 ± 2.36 240.2 ± 10.2 0.345 ± 0.258
Film dispersion method 80.25 ± 1.35 13.82 ± 1.27 189.8 ± 8.9 0.289 ± 0.023

Abbreviations: EE, encapsulation efficiency; LD, drug-loading amount; PDI, particle size.