TABLE 1.

Summary of reviewed published literature of CT colonography by calculation of median test properties* across five target organ sites, stratified by screening and non-screening populations, through 2010.

Target organ No. of studies False positive rate (per 100) Prevalence (per 1000) Positive Predictive Value (per 100)
Renal
 Screening 6 1.0 0.6 1.5
 Non-screening 13 1.0 4.2 25.0
 Mixed/Unknown 3 - - -
 Overall 22 1.1 2.2 20.5
Lung
 Screening 6 0.2 0.1 20.0
 Non-screening 6 0.7 0.7 0
 Mixed/Unknown 3 - - -
 Overall 15 0.7 0.1 3.8
Liver
 Screening 4 0 1.2 0
 Non-screening 8 1.8 0 0
 Mixed/Unknown 2 - - -
 Overall 14 1.3 0 0
Pancreas
 Screening 2 0.1 0 0
 Non-screening 5 1.4 1.2 25.0
 Mixed/Unknown 1 - - -
 Overall 8 0.5 0.5 0
Ovary
 Screening 5 1.5 0 0
 Non-screening 9 3.7 0 10.0
 Mixed/Unknown 1 - - -
 Overall 15 2.5 0 0
*

Summarized across studies with available data for the calculation.

- cannot be calculated due to missing data on the number of true positive results.