Skip to main content
. 2013 May 16;4:57. doi: 10.3389/fneur.2013.00057

Figure 6.

Figure 6

The stochastic behavior of the phase synchronization index (SI) for the subject #2 in all EEG bands for three different days. Notice that for the low gamma band, stochastic activity is higher in and near to the seizure area on all 3 days while for the beta band, it is higher on the second and the third day. This behavior is not strong for theta and alpha bands.