Skip to main content
. 2013 May 21;8(5):e62225. doi: 10.1371/journal.pone.0062225

Table 8. Detection limit of the EPR signal for experimental resins and mixtures, expressed as the time period needed for disappearance of the signal under the measurements conditions.

Experimental resins X-band detection threshold L-band detection threshold
G 100% >6 months >5 months
T 100% 2 months 0 day
U 100% >6 months >5 months
E-15 100% 1 day 0 day
E-2 100% 1 month 16 days
G/T 0.3582/0.6418 >6 months 3 months
G/T 0.5659/0.4341 >6 months 3 months
G/U 0.3582/0.6418 >6 months 3 months
G/U 0.5659/0.4341 >6 months 3 months
G/E-15 0.3582/0.6418 2 days 1 hour
G/E-15 0.5659/0.4341 1 month 3 days
G/T/U/E-15 0.5660/0.2340/0.1/0.1 >6 months 3 months
G/T/U/E-15 0.5660/0.1340/0.15/0.15 >6 months 3 months
G/U/E-15 0.5660/0.2170/0.2170 5 months 3 months

The mass of the sample was 30 mg, a typical medium size restoration on an incisor. G: Bis-GMA, T: TEGDMA, U: UDMA, E-15: Bis-EMA (15-ethoxy/phenol), E-2: Bis-EMA (2-ethoxy/phenol).