Table 3.
CT | MRI | |
---|---|---|
Benign thrombus | There is no enhancement on contrast enhanced CT. | Lower signal intensity on T2W MRI compared to malignant thrombus. There are no significant lower ADC values. |
Malignant thrombus | The presence of enhancement is a strong proof of malignant thrombus. | Higher signal intensity on T2W MRI compared to benign thrombus. Similar signal intensity and ADC values to those of the primary mass. Lower ADC values similar to the primary mass. |