Table 2.
Diagnostic accuracy for computer-generated lesion maps, qualitative color map analysis alone, and qualitative analysis in conjunction with computer-generated lesion maps to exclude areas not detected on the latter
| Computer-generated lesion maps (%) | Qualitative analysis (%) | Qualitative analysis and computer lesion maps (%) | |
|---|---|---|---|
| Study sensitivity | 83 (0.95 CI 58–96) | 70 (0.95 CI 46–87) | 67 (0.95 CI 43–85) |
| Study specificity | 21 (0.95 CI 11–36) | 69 (0.95 CI 53–81) | 80 (0.95 CI 64–90) |
| Negative predictive value | 77 (0.95 CI 46–94) | 84 (0.95 CI 67–93) | 83 (0.95 CI 68–92) |
| Positive predictive value | 29 (0.95 CI 18–43) | 50 (0.95 CI 31–69) | 61 (0.95 CI 39–80) |
CI confidence interval