. 2013 May 17;6:19. doi: 10.1186/1757-1146-6-19

Table 5.

Mean values (SD) and percentage change for the 1st MTPJ, lateral forefoot and hallux at week 0 (N = 30)

1st MTPJ
 
Peak pressure (kPa)
Maximum force (%BW)
Contact area (cm2)
Insert Mean (SD) % change p-value Mean (SD) % change p-value Mean (SD) % change p-value
Shoe only (control)
179.7 (56.3)
n/a
n/a
16.5 (6.9)
n/a
n/a
10.0 (1.3)
n/a
n/a
Customised foot orthosis
176.2 (51.6)
−2%
1.000
17.1 (5.4)
+4%
1.000
10.6 (1.0)
+6%
0.425
Contoured polyethylene
176.2 (46.6)
−2%
1.000
16.7 (5.4)
+1%
1.000
10.7 (1.0)
+6%*
0.020
Contoured EVA
169.1 (49.7)
−6%
0.074
16.0 (5.8)
−3%
1.000
10.6 (1.0)
+5%
0.096
Flat EVA
171.3 (49.8)
−5%
1.000
16.7 (5.7)
+1%
1.000
10.7 (1.0)
+6%
0.061
Lateral forefoot
 
Peak pressure (kPa)
Maximum force (%BW)
Contact area (cm2)
Insert
Mean (SD)
% change
p-value
Mean (SD)
% change
p-value
Mean (SD)
% change
p-value
Shoe only (control)
204.8 (66.1)
n/a
0.194
30.8 (9.2)
n/a
n/a
18.3 (1.5)
n/a
n/a
Customised foot orthosis
191.6 (54.1)
−6%
0.194
30.1 (5.9)
−2%^
1.000
18.5 (1.7)
+1%
0.252
Contoured polyethylene
205.2 (56.2)
0%†+
1.000
32.9 (7.2)
+7%*#†+
0.048
18.5 (1.6)
+1%
0.444
Contoured EVA
193.3 (56.9)
−6%^
0.665
30.9 (7.7)
0%^
1.000
18.5 (1.7)
+1%
0.252
Flat EVA
191.8 (58.2)
−6%^
0.177
30.8 (6.9)
0%^
1.000
18.5 (1.7)
+1%
0.533
Hallux
 
Peak pressure (kPa)
Maximum force (%BW)
Contact area (cm2)
Insert
Mean (SD)
% change
p-value
Mean (SD)
% change
p-value
Mean (SD)
% change
p-value
Shoe only (control)
248.2 (58.9)
n/a
n/a
29 .0(4.8)
n/a
n/a
14.3 (1.2)
n/a
n/a
Customised foot orthosis
258.6 (79.8)
+4%
1.000
29.2 (5.3)
+1%
1.000
14.1 (1.3)
−1%
1.000
Contoured polyethylene
256.3 (91.0)
+3%
1.000
28.2 (5.8)
−3%
1.000
14.2 (1.2)
0%
1.000
Contoured EVA
259.4 (96.5)
+5%
1.000
28.9 (5.5)
0%
1.000
14.2 (1.3)
0%
1.000
Flat EVA 260.0 (94.8) +5% 1.000 29.3 (5.4) +1% 1.000 14.3 (1.1) 0% 1.000

* Mean difference significant at the 0.05 level (Bonferroni adjusted) compared to the shoe only condition.

# Mean difference significant at the 0.05 level (Bonferroni adjusted) compared to the customised orthosis

Mean difference significant at the 0.05 level (Bonferroni adjusted) compared to the flat EVA sham orthosis.

+ Mean difference significant at the 0.05 level (Bonferroni adjusted) compared to the contoured EVA sham orthosis.

^ Mean difference significant at the 0.05 level (Bonferroni adjusted) compared to the contoured polyethylene orthosis.