TABLE V.
Parameter values for power-law fits to the TBOAE latency data and amount of variance accounted for by the fits. Approximate uncertainties (i.e., 95% confidence interval) for the parameter values are included. When the TBOAE latency estimates are reliable (frequency-dependent stimulus duration and stimulus duration = 2.83 ms), their frequency and level dependence is similar to that of ABR forward latency. The power-law fits account for at least 82% of the variance in the data.
| Stimulus duration | b (ms) | c | d | R2 statistic |
|---|---|---|---|---|
| Frequency-dependent | 20.56 ± 2.85 | 6.44 ± 1.54 | 0.34 ± 0.06 | 0.84 |
| 4.00 ms | 19.00 ± 1.44 | 4.75 ± 0.65 | 0.04 ± 0.06 | 0.94 |
| 2.83 ms | 20.41 ± 2.27 | 6.06 ± 1.07 | 0.37 ± 0.08 | 0.93 |
| 2.00 ms | 16.40 ± 4.16 | 9.32 ± 2.91 | 0.00 ± 0.15 | 0.82 |