Skip to main content
. 2013 May 16;33(6):441–449. doi: 10.1007/s40261-013-0085-x

Table 2.

Treatment comparisons of pharmacokinetic metrics

Parameter ORF-C vs ORF-F ORF-F vs OC-F ORF-C vs OC-F
C max (ng/mL) Mean ratio of PK metric (90 % CI) 86.3 (76.91, 96.78) 77.6 (69.27, 87.02) 67.0 (59.76, 75.07)
AUC (ng·h/mL) Mean ratio of PK metric (90 % CI) 103.0 (91.64, 116.10) 97.4 (86.56, 109.50) 100.0 (89.29, 112.94)

Treatment groups were ORF-C 10 mg (n = 29), ORF-F (n = 29), and OC-F 10 mg (n = 30)

AUC area under the plasma concentration-time curve extrapolated to infinity; CI confidence interval, C max maximum observed plasma concentration, OC-F finely crushed original formulation of oxycodone HCl controlled release, ORF-C coarsely crushed reformulated oxycodone HCl controlled release, ORF-F finely crushed reformulated oxycodone HCl controlled release, PK pharmacokinetic