Skip to main content
. 2013 May 17;4:2041731413490182. doi: 10.1177/2041731413490182

Table 2.

Summary of strain at 30 N, ultimate tensile stress, and Young’s modulus (average ± standard deviation) of PADM firm over time (confirmatory study).

Day Average ultimate tensile stress load (N/cm) Average ultimate tensile stress (MPa) Strain at 30 N Average Young’s modulus (MPa)
0 255 ± 21 17.6 ± 4.5 0.10 ± 0.02 71.3 ± 6.2
7 346 ±18 22.1 ± 1.1 0.13 ± 0.02 86.7 ± 9.6
14 216 ± 42 14.3 ± 2.5 0.16 ± 0.03 58.6 ± 8.2
21 197 ± 29 13.7 ± 1.7 0.18 ± 0.02 61.0 ± 5.9
28 119 ± 26 7.9 ± 1.7 0.22 ± 0.09 36.4 ± 8.0
35 158 ± 31 10.2 ±1.7 0.16 ± 0.04 50.3 ± 6.6
42 194 ± 25 11.7 ± 1.7 0.14 ± 0.02 53.0 ± 8.1

PADM: porcine-derived acellular dermal matrix.

On average, there was an initial decrease up until day 28 of implantation followed by a significant increase between days 28 and 42 in both ultimate tensile stress and Young’s modulus.