Skip to main content
. 2012 Sep 10;2(2):127–132.

Table 3.

The mean values (±SD) of sEMG recorded in microvolts (μV). Vastus lateralis and vastus medialis before (Basic) and during vibration treatment and during leg extension performances together with the mechanical power (Watts) are presented for the operated and non-operated legs of all subjects studied (N=38). The asterisks indicate statistical significance *P<0.05; **P<0.001. The statistical significance between basic and vibration treatment and basic and leg extension performance is also indicated § P<0.001.

Variables Leg

Vibration Operated Non operated

Basic sEMG (μV) 43.1 ± 16.7 48.2 ± 17.8*
Treatment sEMG (μV) §154.6 ± 134.4 § 92.7 ± 49.8**

Leg extension

Basic sEMG (μV) 29.7 ± 15.5 30.0 ± 15.1
Performance sEMG (μV) § 211.9 ± 106.0 § 230.4 ± 123.9
Mechanical Power (W) 73.8 ± 24.4 82.1 ± 24.1**

Values are mean ±SD.

Significance

*

= P<0.05;

**

= P<0.001;

§

= P<0.001