Table I.

Energy and kinetic parameters of GCN4 coiled coils measured by pulling from different directions.

Pulling
ends
Contour
length
(nm)
Equilibrium
force (pN)
Equilibrium
rate (1/s)
Transition
state*
(nm)
Unfolding
energy
(kBT)
Rate (1/s)
Folding Unfolding
GCN4-p1C N 25.8 (0.8) 7.5 (0.2) 171 (43) 16.2 (0.8) 12.9 (0.7) 3.7(0.8)×105 0.9 (0.7)
GCN4-p1C’ N 17 (1) 6.6 (0.7) 359 (94) 10 (1) 6.6 (0.6) 2 (1)×104 25 (22)
GCN4-p1N C 23.8 (0.7) 6.3 (0.3) 6 (2) 17.9 (0.9) 8.6 (0.6) 3 (1)×103 0.6 (0.4)
GCN4-p1Nc N & C 7.8 (0.6) 12.1 (0.2) ~0.3 N.A. 8.5 (0.4) N.A. N.A.
*

The contour length distance to the unfolded state.

At zero force