Table 2. Conditions Explored for the RCM Reactions of 7.
| data set | [7]a | [1]a | loading of 1a |
|---|---|---|---|
| 1 | 505.9 mM (500 mM) | 25.7 mM (25 mM) | 5.1 mol % (5.0 mol %) |
| 2 | 491.7 mM (500 mM) | 12.0 mM (12.5 mM) | 2.4 mol % (2.5 mol %) |
| 3 | 507.0 mM (500 mM) | 5.2 mM (5 mM) | 1.0 mol % (1.0 mol %) |
| 4 | 404.5 mM (400 mM) | 14.4 mM (14 mM) | 3.6 mol % (3.5 mol %) |
| 5 | 250.7 mM (250 mM) | 25.9 mM (25 mM) | 10.3 mol % (10.0 mol %) |
| 6 | 250.5 mM (250 mM) | 12.7 mM (12.5 mM) | 5.1 mol % (5.0 mol %) |
| 7b | 121.7 mM (120 mM) | 6.7 mM (6.7 mM) | 5.5 mol % (5.6 mol %) |
| 8b | 121.8 mM (120 mM) | 6.7 mM (6.7 mM) | 5.5 mol % (5.6 mol %) |
| 9b,c | 119.6 mM (120 mM) | 6.7 mM (6.7 mM) | 5.6 mol % (5.6 mol %) |
| 10 | 76.1 mM (75 mM) | 1.2 mM (1.1 mM) | 1.6 mol % (1.5 mol %) |
| 11 | 50.2 mM (50 mM) | 5.1 mM (5 mM) | 10.1 mol % (10.0 mol %) |
| 12 | 48.2 mM (50 mM) | 1.2 mM (1.3 mM) | 2.5 mol % (2.5 mol %) |
| 13 | 9.9 mM (10 mM) | 0.1 mM (0.1 mM) | mol % (1.0 mol %) |
Nominal values in parentheses.
Conditions used by Adjiman et al.10
Kinetic data collected using 1H NMR at 600 MHz with 2 scans per data point.