| First Author (year) | Focus | PS/I | Cases | Reconstruction Strategy | Bifur | ILT | Ca | FEA Solver | Pressure | Residual Stress | Element Type | Material Model |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Stringfellow (1987) | PWS and geometry | I | 2 | Cyl and Sphere | N | N | N | Nastran | 100 mmHg | N | Hex-08 | E-3 MPa |
| Di Martino (2003) | Effect of ILT mat. prop. variation | I | 1 | Bell Curve Shaped | N | Y | N | ABAQUS | 120 mmHg | N | Hex-08 | HE |
| Speelman (2007) | Ca effect on AAA biomechanics | PS | 6 | ? | N | Y | Y | ABAQUS | 16 kPa | N | Quad-04 | HE - 59 |
| Truijers (2007) | PWS | PS | 30 | PC, decimation, SS Gaussian variation | N | N | N | ABAQUS | PS | N | S3 (?) | HE - 59 |
| Rodriguez (2008) | Diameter, asym. and mat. Prop. | I | 1 | in Diameter and location of center | N | N | N | ABAQUS | 16 KPa | N | Hex-08 | HE , HEaniso |
| Doyle (2007) | Comparison of Modeling techniques | I | 3 | Marching Cube (Mimics) | N | Y | N | ABAQUS | 120 mmHg | N | S3 | E-4.66 MPa, HE 59 |
| Li (2008) | ILT and Ca effect on AAA biomechanics | PS | 20 | Marching Cube (Simpleware) | Y | Y | Y | ABAQUS | AvgSys | N | Tet-4 (?) | HE - 59 |
| Doyle (2009) | Vessel asym. as diagnostic tool | PS | 15 | Marching Cube (Mimics) | N | N | N | ABAQUS | 120 mmHg | N | S3 (?) | HE - 59 |
| Heng (2008) | PWS in rAAA and eAAA | PS | 70 | PC, Rhino Surface | N | N | N | ANSYS | PS | N | S8 | HE - 59 |