Skip to main content
. 2013 May 28;2013:256060. doi: 10.1155/2013/256060

Table 2.

Systolic and diastolic blood pressure and heart rate before and after the exposure to different noise levels.

Noise level Variable Mean (SD) before exposure Mean (SD) after exposure P-value*
85 dB Systolic blood pressure (mmHg) 117.38 (12.32) 115.75 (11.09) 0.564
Diastolic blood pressure (mmHg) 73.87 (10.78) 74.12 (8.69) 0.925
Heart rate (bpm) 74.5 (8.33) 71.5 (13.06) 0.200

95 dB Systolic blood pressure (mmHg) 111.88 (7.52) 112.12 (5.81) 0.889
Diastolic blood pressure (mmHg) 69.37 (4.68) 69.75 (4.97) 0.623
Heart rate (bpm) 74.5 (9.85) 71.75 (9.43) 0.147

105 dB Systolic blood pressure (mmHg) 109.37 (12.51) 111.87 (9.81) 0.445
Diastolic blood pressure (mmHg) 69 (6.5) 71.5 (6.54) 0.308
Heart rate (bpm) 71.12 (9.26) 70.87 (11.03) 0.895

*Paired t-test.