Published in final edited form as: Crit Care Med. 2011 Mar;39(3):527–532. doi: 10.1097/CCM.0b013e318206b99b

Table 3. Physiologic variables at failure of mechanical ventilation or peak lung injury while being supported with SAVe I or Siemens 900C. (n=6).

Variable Servo SAVe I
PaO2, torr 106.0 ± 25.6* 52.0 ± 11.1*
PaCO2, torr 57.8 ± 11.3 56.3 ± 19.7
VE, L/min 5.9 ± 2.0 5.5 ± 1.1
Compliance, ml/cm H2O 8.8 ± 1.9 5.9 ± 2.9
PaO2/FIO2 ratio 147.2 ± 71.1 93.2 ± 33.2
Mean BP, mm Hg 97.3 ± 18.4 106.7 ± 25.9
Mean pulmonary artery
pressure, mm Hg
35.1 ± 9.1 46.7 ± 17.2
Cardiac Output, L/min 1.55 ± 0.53 1.71 ± 0.51
PAOP, mm Hg 12.50 ± 4.04 14.30 ± 6.06
PEEP, cm H2O 6.7 ± 3.2 0
FIO2 0.80 ± 0.25 0.58 ± 0.06
Peak airway pressure,
cm H2O
30.8 ± 7.2 29.5 ± 6.9

Values are mean ± SD. Comparisons are made between Siemens Servo and SAVe I ventilator. p>0.05 unless specified.

*

p=0.002

p=0.003.