Skip to main content
. Author manuscript; available in PMC: 2013 Jun 20.
Published in final edited form as: Semin Nucl Med. 2008 Jan;38(1):67–81. doi: 10.1053/j.semnuclmed.2007.09.006

Table 3.

Camera-Based MAG3 Clearances (mL/min/1.73 m2)

Sex N Mean SD Minimum 5th Percentile 95th Percentile Maximum
MAG3 clearance* M 44 338 63 211 238 433 454
F 62 309 71 188 226 439 503
All subjects 106 321 69 188 226 439 503

SD, standard deviation.

Reprinted with permission from Esteves et al.45

*

The difference is significant (P < 0.05) between males and females.