Table 1.

Comparative analysis of LV function between groups at baseline and at 6 wk after MI

Operator-driven instructions Standardized protocol P
Baseline End-diastolic volume (mL) 49 ± 8 50 ± 8 0.80
End-systolic volume (mL) 20 ± 4 22 ± 4 0.11
Ejection fraction (%) 60 ± 3 55 ± 3 0.26
6 wk after MI End-diastolic volume (mL) 79 ± 21 71 ± 15 0.26
End-systolic volume (mL) 48 ± 19 45 ± 11 0.56
Ejection fraction (%) 41 ± 8 38 ± 7 0.26