Desired number of hESCs/hiPSCs per EB | AggreWell™ 400 plate eight wells, each with approximately 1,200 microwells per well |
---|---|
Required number of hESCs/hiPSCs per well | |
50 | 6 × 104 cells |
100 | 1.2 × 105 cells |
200 | 2.4 × 105 cells |
500 | 6 × 105 cells |
1,000 | 1.2 × 106 cells |
2,000 | 2.4 × 106 cells |
3,000 | 3.6 × 106 cells |
4,000 | 4.8 × 106 cells |