Table 3.
Effect of changes in fiber distribution on the active contraction component alone for Hearts 1 and 2. Changes in inclination angle had a direct effect upon the strain predictions for the SNR 0.1 cases, particularly in the circumferential direction strain predictions.
| Cir. strain | Radial strain | |||
|---|---|---|---|---|
| %RMSE | R 2 | %RMSE | R 2 | |
| Heart 1 | ||||
| Validation study | 0.098 | 0.813 | 0.138 | 0.780 |
| SNR 0.1 normal fiber | 0.131 | 0.786 | 0.145 | 0.750 |
| SNR 0.1 + 5% IA | 0.212 | 0.745 | 0.144 | 0.735 |
| SNR 0.1 − 5% IA | 0.160 | 0.753 | 0.142 | 0.737 |
|
| ||||
| Heart 2 | ||||
| Validation study | 0.093 | 0.830 | 0.113 | 0.780 |
| SNR 0.1 normal fiber | 0.114 | 0.790 | 0.124 | 0.770 |
| SNR 0.1 + 5% IA | 0.156 | 0.630 | 0.214 | 0.600 |
| SNR 0.1 − 5% IA | 0.247 | 0.302 | 0.331 | 0.500 |
IA: inclination angle.