Skip to main content
. Author manuscript; available in PMC: 2014 Jun 15.
Published in final edited form as: Methods. 2013 Mar 13;61(3):219–226. doi: 10.1016/j.ymeth.2013.03.004

Figure 5.

Figure 5

Figure 5

Results of CAMV applied to quantitative tyrosine phosphorylation dataset. (A) All peptide matches following user validation of the dataset. Color code: Agreement between algorithm and user 201/317(green), alternate identification chosen by user 4/317 (yellow), additional assignment included by user 79/317 (blue), and assignment rejected by user 33/317 (red). (B) Distribution of user and CAMV decisions versus MASCOT score. Note that in many cases the user rescued the spectra that were pre-emptively excluded by the software, while in other cases the user rejected the spectral assignment based on the poor quality of the match.