Skip to main content
. Author manuscript; available in PMC: 2014 Jul 9.
Published in final edited form as: J Am Coll Cardiol. 2013 Apr 3;62(2):138–147. doi: 10.1016/j.jacc.2013.03.021

Table 2.

Results of FIRM Mapping

Characteristic Any Source Ablation (n=61) No Source Ablation (n=33) P
No. Concurrent Sources/patient 2.3±1.1 1.8±0.6 0.02
Left Atrial Sources 107 (69.9%) 31 (58.5%) 0.13
Right Atrial Sources 46 (30.1%) 22 (41.5%)
Left Atrial Sources
Rotors 73 (47.7%) 27 (50.9%) 0.03
Focal Sources 34 (22.2%) 4 (7.5%)
Near Pulmonary Veins 37/153 (24.2%) 10/53 (18.9%) 0.28
Left Atrial Roof 28/153 (18.3%) 5/53 (9.4%) 0.08
Right Atrial Sources
Rotors 42 (27.5%) 21 (39.6%) 1.00
Focal Sources 4 (2.6%) 1 (1.9%)
Lateral/Posterior 34/153 (22.2%) 15/53 (28.3%) 0.77
Medial/septal 12/153 (7.8%) 7/53 (13.2%)

Values are mean ± SD or n(%) compared with t-tests or Fisher exact, respectively.