Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2014 May 1.
Published in final edited form as: Infect Control Hosp Epidemiol. 2013 May;34(5):466–471. doi: 10.1086/670215

Decontamination of Targeted Pathogens from Patient Rooms Using an Automated Ultraviolet-C-Emitting Device

Deverick J Anderson 1,2, Maria F Gergen 3, Emily Smathers 2, Daniel J Sexton 1,2, Luke F Chen 1,2, David J Weber 3,4, William A Rutala 3,4; CDC Prevention Epicenters Program
PMCID: PMC3703853  NIHMSID: NIHMS477180  PMID: 23571362

Abstract

OBJECTIVE

To determine the effectiveness of an automated ultraviolet-C (UV-C) emitter against vancomycin-resistant enterococci (VRE), Clostridium difficile, and Acinetobacter spp. in patient rooms.

DESIGN

Prospective cohort study.

SETTING

Two tertiary care hospitals.

PARTICIPANTS

Convenience sample of 39 patient rooms from which a patient infected or colonized with 1 of the 3 targeted pathogens had been discharged.

INTERVENTION

Environmental sites were cultured before and after use of an automated UV-C-emitting device in targeted rooms but before standard terminal room disinfection by environmental services.

RESULTS

In total, 142 samples were obtained from 27 rooms of patients who were colonized or infected with VRE, 77 samples were obtained from 10 rooms of patients with C. difficile infection, and 10 samples were obtained from 2 rooms of patients with infections due to Acinetobacter. Use of an automated UV-C-emitting device led to a significant decrease in the total number of colony-forming units (CFUs) of any type of organism (1.07 log10 reduction; P < .0001), CFUs of target pathogens (1.35 log10 reduction; P < .0001), VRE CFUs (1.68 log10 reduction; P < .0001), and C. difficile CFUs (1.16 log10 reduction; P < .0001). CFUs of Acinetobacter also decreased (1.71 log10 reduction), but the trend was not statistically significant (P = .25). CFUs were reduced at all 9 of the environmental sites tested. Reductions similarly occurred in direct and indirect line of sight.

CONCLUSIONS

Our data confirm that automated UV-C-emitting devices can decrease the bioburden of important pathogens in real-world settings such as hospital rooms.


The hospital environment is receiving increasing attention as a source for acquisition and spread of pathogens among hospitalized patients. In particular, 4 key organisms appear to survive in the environment long enough to place patients at risk. Vegetative bacteria such as methicillin-resistant Staphylococcus aureus (MRSA),1,2 vancomycin-resistant enterococci (VRE),3 and Acinetobacter spp.46 may persist on environmental surfaces for days or weeks. Clostridium difficile spores can persist on environmental surfaces for up to 5 months.7 In fact, acquisition of these organisms from the environment has previously been demonstrated, particularly when a patient is admitted to a room from which a patient colonized or infected with these important pathogens was just discharged.811

Standard approaches to environmental cleaning are inadequate.1214 As a result, new, automated technologies are being investigated to determine how best to enhance terminal room disinfection of the hospital environment. One such technology is ultraviolet (UV) radiation. UV-C light near a wavelength of 254 nm induces the formation of pyrimidine dimers from thymine and cytosine.15 These dimers in turn cause breaks in microbial DNA that make genetic replication impossible, thus destroying the organisms or rendering them unable to grow or reproduce.16

The evidence that automated UV-C emitters can enhance disinfection of the hospital environment is growing. To date, authors of previously published studies have demonstrated that UV-C can effectively eradicate MRSA, VRE, Acinetobacter, and C. difficile under experimental conditions.1520 To our knowledge, however, only 2 studies have evaluated the effectiveness of automated UV-C emitters in real hospital environments.19,21 These studies confirmed that the automated UV-C emitter reduced the bioburden of MRSA, VRE, and C. difficile in clinical settings.19,21

The objective of this study was to add to this growing literature by (1) determining the effectiveness of an automated UV-C emitter against VRE and C. difficile in a multicenter clinical environment and (2) evaluating the effectiveness of this automated UV-C emitter against Acinetobacter spp. in real-world clinical settings.

METHODS

This study was performed at 2 tertiary acute care hospitals, Duke University Medical Center (753 beds) and the University of North Carolina Health Care (804 beds), from July 2011 through September 2012. The study protocol was reviewed by institutional review board committees at both institutions and determined to be exempt.

We performed an interventional study on a convenience sample of hospital rooms. Three pathogenic organisms were targeted: VRE, C. difficile, and Acinetobacter spp. Hospital rooms were identified using microbiological and infection control databases to search for patients placed on contact precautions as a result of colonization or infection with a target organism.

After a targeted room was identified, environmental cultures were obtained after patient discharge but before standard terminal room disinfection by environmental services personnel. A minimum of 5 environmental sites were cultured in triplicate from each room, using Rodac plates. The 5 environmental sites targeted for culture included the bedside rail, bedside table, chair arm, overbed table, and sink counter. When one of these surfaces was not available, supply carts were cultured. The toilet, shower floor, and floor adjacent to the toilet were also cultured in targeted rooms from which a patient with C. difficile infection was just discharged. Each environmental culture site was assessed and recorded as in either direct or indirect line of sight of the automated UV-C-light-emitting device. The automated UV-C-emitting device was then used in the room. Environmental cultures were repeated in triplicate from the same environmental sites, following application of UV-C light. Following these cultures, environmental services performed a standard terminal room disinfection per standard hospital protocol, and the room was made available for the next patient.

Automated UV-C-Emitting Device

Each institution had access to 1 automated UV-C-emitting device (Tru-D SmartUVC; Lumalier). The automated UV-C device emits light at a wavelength of 254 nm and measures the reflected dose of light, using 8 sensors mounted on the device. Each device was programmed to deliver a reflected dose of 12,000 μWs/cm2 for vegetative bacteria (VRE or Acinetobacter) or 22,000 μWs/cm2 for spores (C. difficile). The device was operated by trained study personnel. The device was rolled into the targeted room and placed approximately in the center of the room. Care was taken to ensure that drawers and cabinets were opened before using the machine. In particular, the UV-C device was placed in a location to ensure that light was emitted into the room’s bathroom whenever possible. The time required for the device to deliver the above minimum reflected doses was measured.

Microbiological Methods

Dey/Engley (D/E) Neutralizing Agar or Clostridium difficile Selective Agar was used in the Rodac plates. All plates were incubated at 37°C for 48 hours; all C. difficile plates were incubated anaerobically. For patient rooms targeted for vegetative bacteria, 2 quantitative microbiologic outcomes were determined: the total number of colony-forming units (CFUs) of any organism present on each plate and the total number of CFUs of the targeted pathogen present on each plate. For C. difficile, only the total number of CFUs of the targeted pathogen present on each plate was determined. In either scenario, the number of targeted pathogens was quantified by first identifying morphologies suggestive of the target organisms. These colonies were then subcultured and identified using standard microbiological methods.

Statistical Methods

Standard descriptive statistics were used, including medians and interquartile ranges (IQRs) for non-normally distributed continuous variables. The Wilcoxon signed rank sums test was used to determine differences between the number of CFUs before and after use of the UV-C device. For these analyses, quantitative results from triplicate cultures were aggregated so that the comparison unit for statistical comparison was the number of CFUs per environmental site, not per plate. The McNemar test was used to determine differences between the proportions of positive plates before and after use of the UV-C device.

RESULTS

We sampled 229 environmental surfaces from the rooms of 39 patients during the 15-month study period. In total, 142 samples were obtained from 27 rooms of patients who were colonized or infected with VRE, 77 samples were obtained from 10 rooms of patients with C. difficile infection, and 10 samples were obtained from 2 rooms of patients with infections due to Acinetobacter. The median time for the UV-C vegetative cycle to be completed was 25 minutes (IQR, 20–35); the median time for the UV-C spore cycle to be completed was 45 minutes (IQR, 42–61).

The total number of CFUs of any type of pathogen detected on culture plates from all sampled environmental sites decreased from 28,642 to 2,444 following use of the UV-C device (1.07 log10 reduction; Table 1). The median number of CFUs per sample decreased from 110 (IQR, 49–251) to 4 (IQR, 1–11) following use of the UV-C device (P < .0001). Similarly, the total number of CFUs of target organisms from all cultured environmental sites decreased from 1,488 to 66 following use of the UV-C device (1.35 log10 reduction; P < .0001). A greater than 1 log10 overall reduction was achieved for all 3 target organisms following use of the UV-C device. VRE CFUs decreased from 712 to 15 following use of the UV-C device (1.68 log10 reduction; P < .0001), C. difficile CFUs decreased from 724 to 51 (1.16 log10 reduction; P < .0001), and Acinetobacter decreased from 52 to 1 (1.71 log10 reduction; P = .25; Table 1).

TABLE 1.

Efficacy of Ultraviolet-C (UV-C) Decontamination in 39 Patient Rooms That Had Been Occupied by Patients under Contact Precautions for 3 Target Organisms (Vancomycin-Resistant Enterococci [VRE], n = 27; Clostridium difficile [CD], n = 10; Acinetobacter spp. [AB], n = 2): Reduction in Colony-Forming Units (CFUs) and Comparison of Decontamination in Direct versus Indirect Line of Sight

Overall (direct and indirect combined)
Direct
Indirect
Pb
No. of samplesa CFUs before UV-C (log10) CFUs after UV-C (log10) Decontamination, log10 red No. of samples CFUs before UV-C (log10) CFUs after UV-C (log10) Decontamination, log10 red No. of samples CFUs before UV-C (log10) CFUs after UV-C (log10) Decontamination, log10 red
Total CFUs 152 28,642 (4.46) 2,444 (3.39) 1.07 143 26,656 (4.43) 2,276 (3.36) 1.07 9 1,986 (3.30) 168 (2.23) 1.07 .24
All target organisms 229 1,488 (3.17) 66 (1.82) 1.35 194 782 (2.89) 19 (1.28) 1.61 35 706 (2.85) 47 (1.67) 1.18 .11
VRE 142 712 (2.85) 15 (1.18) 1.68 135 712 (2.85) 15 (1.18) 1.68 8 0 0 .15
CDI 77 724 (2.86) 50 (1.70) 1.16 51 19 (1.28) 3 (0.48) 0.80 26 705 (2.85) 47 (1.67) 1.18 .51
AB 10 52 (1.71) 1 (0) 1.71 9 51 (1.71) 1 (0) 1.71 1 1 0 .41

NOTE. CDI, Clostridium difficile infection.

a

Samples are aggregated so that triplicate cultures are counted as 1 sample.

b

P value determined by Wilcoxon signed rank sums test comparing CFUs/sample in direct versus indirect line of sight.

A greater than 1 log10 reduction was observed in cultures obtained from sites in both direct and indirect line of site for total CFUs of any organism, total CFUs of the 3 targeted organisms, VRE CFUs, and Acinetobacter CFUs (Table 1). A 0.80 log10 reduction was observed for C. difficile in direct line of sight, but a 1.18 log10 reduction was observed in indirect line of sight. No statistically significant differences were observed in the reductions that occurred in direct versus indirect line of sight disinfection for any of these categories.

The total number of CFUs was reduced following use of UV-C light at each of the 9 environmental locations tested for total CFUs of any organism and each of the 3 targeted organism (Table 2); the greatest reduction was observed on the overbed table (98%), while the lowest reduction was observed on the bathroom floor adjacent to the toilet (74%). VRE was identified on 49 (11%) of 428 plates before use of the UV-C device and only 6 (1%) of 428 plates afterward (P < .0001; Figure 1). The proportion of C. difficile–positive plates similarly decreased from 10% to 5% (P = .03). While the proportion of Acinetobacter-positive plates decreased from 13% to 3%, this trend was not statistically significant (P = .38).

TABLE 2.

Overall and Organism-Specific Reductions in Colony-Forming Units (CFUs) on 9 Specific Hospital Room Surfaces Following Ultraviolet-C (UV-C) Decontamination in 39 Patient Rooms That Had Been Occupied by Patients under Contact Precautions for Vancomycin-Resistant Enterococci (VRE; n = 27), Clostridium difficile (CD; n = 10), and Acinetobacter spp. (AB; n = 2)

Site No. of samples Total CFUs of any organism
VRE-positive plates (N p 428)
CD-positive plates (N p 225)
AB-positive plates (N p 30)
Before UV-C median (IQR) After UV-C median (IQR) Before UV-C After UV-C Before UV-C After UV-C Before UV-C After UV-C
Bedside rail 37 147 (54–352) 4 (1–21) 10/74 0/75 1/30 2/30 1/6 0/6
Bedside table 39 122 (60–183) 5 (1–9) 7/81 2/81 3/30 1/30 2/6 1/6
Chair arm 40 208 (73–495) 7 (2–23) 10/81 2/81 0/33 1/33 1/6 0/6
Overbed table 40 103.5 (40–176) 2 (1–5) 9/84 1/84 0/30 0/30 0/6 0/6
Sink counter 32 77 (33–129) 5 (2–21) 7/59 0/60 2/30 0/30 0/6 0/6
Supply cart 6 88 (42–316) 8 (1–34) 4/21 1/21
Toilet 15 48 (13–66) 3 (1–8) 0/15 0/15 6/30 3/30
Shower floora 0/15 0/15
Bathroom floor adjacent to toilet 14 100 (83–289) 26 (0.5–160) 2/12 0/12 10/30 4/30

NOTE. CDI, Clostridium difficile infection; IQR, interquartile range.

a

Only tested in CDI rooms, so no total CFUs were calculated.

FIGURE 1.

FIGURE 1

Change in proportion of positive plates for target organisms before and after use of an automated ultraviolet-C emitter.

DISCUSSION

Numerous studies have demonstrated that current strategies for terminal room disinfection are inadequate. In fact, 50% or more hospital surfaces may go untouched and uncleaned following terminal room disinfection.12 UV-C light is a novel method to enhance terminal disinfection of hospital rooms. Our multicenter, prospective study confirms that automated UV-C emitters substantially decrease the bioburden of important pathogens, such as VRE and C. difficile, from patient rooms in real-world settings. In addition, our data suggest that an automated UV-C emitter can help reduce the bio-burden of Acinetobacter spp. It was likely that the reduction in the bioburden of Acinetobacter spp. was not statistically significant because of the low frequency of Acinetobacter infection in our study hospitals.

Authors of several studies have investigated the efficacy of automated UV-C emitters against important pathogens in nonclinical, experimental conditions.1517 For example, Boyce et al18 used a quantitative disk carrier method to evaluate the efficacy of UV-C light emitters in reducing the burden of C. difficile spores in patient rooms. Disks inoculated with 105 to 106 nontoxigenic C. difficile spores were placed in specific locations in 25 patient rooms and then exposed to light from an automated UV-C-emitting device. C. difficile spores were reduced between 1.4 and 2.9 log10.18

To our knowledge, however, only 2 previously published studies have evaluated the effectiveness of automated UV-C emitters in clinical conditions following patient discharge. Rutala et al19 cultured 10 targeted environmental surfaces in 8 rooms of patients previously placed in contact precautions because of colonization or infection with MRSA. An automated UV-C-emitting device was used before cleaning. UV-C irradiation led to decreases in total CFUs per culture plate, in the number of samples positive of MRSA, and in MRSA counts per plate.19 Nerandzic et al21 performed a similar experiment in 66 rooms of patients previously placed in contact precautions for MRSA or C. difficile. The proportion of sites positive for MRSA or C. difficile significantly decreased following UV-C irradiation. While the proportion of surfaces positive for VRE decreased from 2.7% to 0.4%, this trend was not statistically significant (P = .07).21

Our multicenter study utilized similar methods and confirmed that application of measured doses of UV-C light produced greater than 1 log10 reductions in the bioburden of C. difficile spores. These reductions also were observed from environmental sites in both direct and indirect line of sight locations relative to the portable UV-C-light-emitting device. Unlike the study by Nerandzic et al,21 we also targeted and sampled patient rooms from which a patient on contact precautions for VRE had been discharged. In this setting, UV-C light led to a 1.68 log10 reduction in colony counts of VRE at sampled environmental sites.

We are not aware of prior studies that have evaluated the efficacy of automated UV-C emitters in reducing the environmental bioburden of Acinetobacter in clinical settings such as patient rooms. In our study, UV-C light led to a 1.71 log10 reduction in the environmental bioburden of Acinetobacter. Similarly, the proportion of sampled locations positive for Acinetobacter decreased from 13% to 1%. Unfortunately, we were able to enroll only 2 rooms for Acinetobacter that met enrollment criteria during our study. Thus, our analysis was statistically underpowered.

Our results and the results cited above demonstrate that UV-C is less effective at killing bacteria in clinical settings compared with experimental, nonclinical conditions. For example, the application of UV-C light via automated devices has been shown to decrease the bioburden of MRSA, VRE, C. difficile, and Acinetobacter by 3–4 log10 in experimental conditions (eg, inoculated formica sheets or discs).19 In contrast, the use of an automated UV-C light emitter produced a 1.07 log10 reduction in total CFUs and a 1.35 log10 reduction in targeted pathogens in our study. Because cultures were obtained before and after application of UV-C light in rooms that had not undergone standard cleaning and disinfection, it is possible that the efficacy of UV-C was adversely affected by the presence of dirt and debris on surfaces and equipment. For example, the authors of a recent study of the efficacy of hand-held UV-C devices reported that these devices were ineffective for the disinfection of 72% of the 68 computer keyboards located in hospital wards if mechanical cleaning was not performed before attempted disinfection with UV-C light.22 In another study, UV-C was effective in disinfecting ultrasound probes only if it was applied after surfaces were disinfected with mechanical friction and a chemical disinfectant.23 Nerandzic et al21 previously investigated the effectiveness of an automated UV-C emitter following cleaning by environmental staff. No samples from 26 rooms were contaminated with MRSA following both terminal room disinfection and use of the automated UV-C emitter.21 These studies and our results suggest that UV-C disinfection may be more effective when used after traditional cleaning protocols. Thus, cleaning must remain an important part of terminal room disinfection, but in its absence or on locations missed by cleaning staff, more than 90% of pathogenic bacteria will still be killed when an automated UV-C device is used.

Our study has limitations. First, we utilized a convenience sample of patient rooms from 2 acute care tertiary care hospitals. Thus, our data may not be generalizable to other settings. Second, the minority of our samples identified pathogens of interest. While this may have limited some of our statistical power, our findings are actually consistent with other published studies. That is, in general, approximately 10%–20% of surfaces are typically contaminated with pathogenic bacteria.19,21 Third, we were able to study only 2 rooms of patients infected with Acinetobacter spp., thus limiting the statistical power of our results. Finally, our study did not provide any patient-specific information, thereby limiting our ability to make conclusions about the impact of this technology for specific patient groups (eg, immunocompromised patients).

The use of UV-C radiation in medical settings is expanding to novel settings and through novel methods. For example, UV-C has recently been used to decontaminate specific rooms in long-term care facilities24 and has been trialed with hand-held devices.22,25 Our data support and expand on previously published studies to confirm that automated UV-C-emitting devices can decrease the bioburden of important pathogens in hospital rooms. Whether this method actually leads to improved patient safety, decreased acquisition of pathogenic bacteria, and decreased rates of health care–associated infections remains to be seen.

Acknowledgments

We would like to thank Lumalier for donating 2 Tru-D devices for use during this study. Lumalier did not provide funding for the study and did not contribute to the study design or writing of the manuscript.

Financial support. The study was funded by the Centers for Disease Control and Prevention (CDC) Prevention Epicenters Program (U54CK000164). Colleagues from the CDC assisted in the review of study design but not did participate in manuscript preparation, submission, or review. D.J.A. reports that he has received additional grant support from the National Institutes of Health/National Institute of Allergy and Infectious Diseases (K23AI095357), the Robert Wood Johnson Foundation, and Merck.

Footnotes

Potential conflicts of interest. All authors report no conflicts of interest relevant to this article. All authors submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest, and the conflicts that the editors consider relevant to this article are disclosed here.

References

  • 1.Cohen AL, Calfee D, Fridkin SK, et al. Recommendations for metrics for multidrug-resistant organisms in healthcare settings: SHEA/HICPAC position paper. Infect Control Hosp Epidemiol. 2008;29(10):901–913. doi: 10.1086/591741. [DOI] [PubMed] [Google Scholar]
  • 2.Neely AN, Maley MP. Survival of enterococci and staphylococci on hospital fabrics and plastic. J Clin Microbiol. 2000;38(2):724–726. doi: 10.1128/jcm.38.2.724-726.2000. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Weber DJ, Rutala WA. Role of environmental contamination in the transmission of vancomycin-resistant enterococci. Infect Control Hosp Epidemiol. 1997;18(5):306–309. doi: 10.1086/647616. [DOI] [PubMed] [Google Scholar]
  • 4.Catalano M, Quelle LS, Jeric PE, Di Martino A, Maimone SM. Survival of Acinetobacter baumannii on bed rails during an outbreak and during sporadic cases. J Hosp Infect. 1999;42(1):27–35. doi: 10.1053/jhin.1998.0535. [DOI] [PubMed] [Google Scholar]
  • 5.Jawad A, Seifert H, Snelling AM, Heritage J, Hawkey PM. Survival of Acinetobacter baumannii on dry surfaces: comparison of outbreak and sporadic isolates. J Clin Microbiol. 1998;36(7):1938–1941. doi: 10.1128/jcm.36.7.1938-1941.1998. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Musa EK, Desai N, Casewell MW. The survival of Acinetobacter calcoaceticus inoculated on fingertips and on formica. J Hosp Infect. 1990;15(3):219–227. doi: 10.1016/0195-6701(90)90029-n. [DOI] [PubMed] [Google Scholar]
  • 7.Kim KH, Fekety R, Batts DH, et al. Isolation of Clostridium difficile from the environment and contacts of patients with antibiotic-associated colitis. J Infect Dis. 1981;143(1):42–50. doi: 10.1093/infdis/143.1.42. [DOI] [PubMed] [Google Scholar]
  • 8.Datta R, Platt R, Yokoe DS, Huang SS. Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants. Arch Intern Med. 2011;171(6):491–494. doi: 10.1001/archinternmed.2011.64. [DOI] [PubMed] [Google Scholar]
  • 9.Drees M, Snydman DR, Schmid CH, et al. Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci. Clin Infect Dis. 2008;46(5):678–685. doi: 10.1086/527394. [DOI] [PubMed] [Google Scholar]
  • 10.Huang SS, Datta R, Platt R. Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med. 2006;166(18):1945–1951. doi: 10.1001/archinte.166.18.1945. [DOI] [PubMed] [Google Scholar]
  • 11.Shaughnessy MK, Micielli RL, DePestel DD, et al. Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol. 2011;32(3):201–206. doi: 10.1086/658669. [DOI] [PubMed] [Google Scholar]
  • 12.Carling PC. Evaluating the thoroughness of environmental cleaning in hospitals. J Hosp Infect. 2008;68(3):273–274. doi: 10.1016/j.jhin.2007.10.023. [DOI] [PubMed] [Google Scholar]
  • 13.Carling PC, Parry MF, Von Beheren SM. Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals. Infect Control Hosp Epidemiol. 2008;29(1):1–7. doi: 10.1086/524329. [DOI] [PubMed] [Google Scholar]
  • 14.Carling PC, Von Beheren S, Kim P, Woods C. Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool. J Hosp Infect. 2008;68(1):39–44. doi: 10.1016/j.jhin.2007.09.015. [DOI] [PubMed] [Google Scholar]
  • 15.Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis. 2010;10:197. doi: 10.1186/1471-2334-10-197. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Conner-Kerr TA, Sullivan PK, Gaillard J, Franklin ME, Jones RM. The effects of ultraviolet radiation on antibiotic-resistant bacteria in vitro. Ostomy Wound Manage. 1998;44(10):50–56. [PubMed] [Google Scholar]
  • 17.Setlow P. Spores of Bacillus subtilis: their resistance to and killing by radiation, heat and chemicals. J Appl Microbiol. 2006;101(3):514–525. doi: 10.1111/j.1365-2672.2005.02736.x. [DOI] [PubMed] [Google Scholar]
  • 18.Boyce JM, Havill NL, Moore BA. Terminal decontamination of patient rooms using an automated mobile UV light unit. Infect Control Hosp Epidemiol. 2011;32(8):737–742. doi: 10.1086/661222. [DOI] [PubMed] [Google Scholar]
  • 19.Rutala WA, Gergen MF, Weber DJ. Room decontamination with UV radiation. Infect Control Hosp Epidemiol. 2010;31(10):1025–1029. doi: 10.1086/656244. [DOI] [PubMed] [Google Scholar]
  • 20.Rastogi VK, Wallace L, Smith LS. Disinfection of Acinetobacter baumannii–contaminated surfaces relevant to medical treatment facilities with ultraviolet C light. Mil Med. 2007;172(11):1166–1169. doi: 10.7205/milmed.172.11.1166. [DOI] [PubMed] [Google Scholar]
  • 21.Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis. 2010;10:197. doi: 10.1186/1471-2334-10-197. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Sweeney CP, Dancer SJ. Can hospital computers be disinfected using a hand-held UV light source? J Hosp Infect. 2009;72(1):92–94. doi: 10.1016/j.jhin.2009.01.019. [DOI] [PubMed] [Google Scholar]
  • 23.Kac G, Podglajen I, Si-Mohamed A, Rodi A, Grataloup C, Meyer G. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol. 2010;31(2):165–170. doi: 10.1086/649794. [DOI] [PubMed] [Google Scholar]
  • 24.Sitzlar B, Vajravelu RK, Jury L, Donskey CJ, Jump RL. Environmental decontamination with ultraviolet radiation to prevent recurrent Clostridium difficile infection in 2 roommates in a long-term care facility. Infect Control Hosp Epidemiol. 2012;33(5):534–536. doi: 10.1086/665310. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Nerandzic MM, Cadnum JL, Eckart KE, Donskey CJ. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis. 2012;12:120. doi: 10.1186/1471-2334-12-120. [DOI] [PMC free article] [PubMed] [Google Scholar]

RESOURCES