Table 4.

Comparison of proposed expert system with the studies in the literature.

Method Performance criteria Maximum classification accuracy
VFI5-GA [6] 10-fold-cross-validation 68%

DTI-HITON 10-fold-cross-validation 71.87%
NN-HITON [7] 60.38%
KNN-HITON 65.30%

OneR 70% train-%30 test 58.09%
J48 [8] 74.26%
Naïve Bayes 75.00%

AIRS-FWP [9] 10-fold-cross-validation
80% train-%20 test
76.20%
80.71%

RF-CBFS [10]
RF-CBFS with random sampling
10-fold-cross-validation 76.30%
90.00%

Proposed expert system (FS-LS-SVM) 10-fold-cross-validation 82.09%