Table 4.
Overview of the limitations of the temperature measurement techniques in gas turbines. Taken from Feist et al. [22].
Method | Disadvantage/Limitation |
---|---|
Thermocouples | Intrusive Limited number Costly installation Bonding to ceramic surfaces Electromagnetic Interference Difficult to use on rotating components |
Thermal Paints | Intrusive Time consuming (calibration and experiment) Irreversible Discrete values and poor resolutionCostly |
Pyrometry | Sensitive to stray light Changes in emissivity Translucency of ceramic coatings Cleanness of optics |
Thermographic Phosphor | Decreasing signals with increasing temperatures Bonding of the phosphor Phosphor coating can be intrusive |