Skip to main content
. 2012 Dec 27;135(1):0110051–0110059. doi: 10.1115/1.4023133

Fig. 5.

Fig. 5

Space- and time-averaged shear (Eq. (3)) in Pa at 5 mm increments along the length of the proximal vein of all four patients. The data point of shear for patient no. 4 located at a distance of 2.5 mm is not shown on the scale but is equal to 12.9 Pa.