Skip to main content
. 2012 Feb 14;134(2):24502–NaN. doi: 10.1115/1.4005693

Fig. 2.

Fig. 2

Experimentally measured displacement-time data were prescribed as displacement history of the rigid indenter in the finite element models of (a) hysteresis and (c) ramp-hold tests. Viscoelastic material properties of the indented tissue were inversely computed by fitting the FE predictions (solid line) in force-time responses to experimental measurements from (b) hysteresis and (d) ramp-hold tests.