Skip to main content
. Author manuscript; available in PMC: 2013 Jul 11.
Published in final edited form as: Rev Environ Health. 2013;28(1):21–35. doi: 10.1515/reveh-2012-0029

Table 1.

Instrumentation used during environmental monitoring.

Parameter Equipment Averaging time
TAPL
 UFPa TSI CPC, Model 3775 1 s
 PM2.5 TSI Sidepak, Model AM510 10 s
 Particle size distribution TSI SMPS, Model 3936L75 120 s
 NO/NOx ThermoElectron, chemiluminescence analyzer, Model 42i 20 s
 CO ThermoElectron gas filter correlation analyzer, Model 48i-TLE 10 s
 pPAH Ecochem PAS, Model 2000CE 8 s
 BC Magee Scientific Aethalometer, Model AE-16 60 s
Fixed site (Somerville)
 UFPa TSI CPC, Model 3781 60 s
 pPAH Ecochem PAS, Model 2000CE
Ecochem PAS, Model 2000
120 s
 Meteorology Vantage Pro2 5 min
a

PNC is measured as the proxy for UFPs.