Skip to main content
. 2013 Jun 19;12:48. doi: 10.1186/1476-069X-12-48

Table 3.

City-specific determinants of hopane concentrations in house settled dust

City Final model with regression coefficients Partial R2 Model Adj.R2
Edmonton
log (hopanes) = 3 – 0.13 cleaning frequency
0.78
0.80
- 1.5 Smooth Flooring
0.78
−0.15 Air Conditioning
0.35
Toronto
Log (hopanes) = 2.69 -1.03 Smooth Flooring
0.29
0.45
−0.008 Elevation
0.13
+ 0.88 Attached Garage −0.66 Detached Garage
0.13%*
Windsor**
log (hopanes) = 5.6 + 0.5 elevation
0.36
0.39
+ 0.17 RD1_100
0.13
Winnipeg
log (hopanes) = 1.45 – 0.057Heating degree days
0.17
0.33
– 1.33 multifamily house
0.16
Vancouver log (hopanes) = 1.9 – 0.09 Heating Degree Days
0.09
0.10
– 0.07 Shoe removal 0.07

* The Garage variable has three categories: No garage, Attached garage and Detached garage.

** In Windsor, elevation and distance to the Ambassador Bridge were strongly and significantly correlated. An alternative model with Distance to Ambassador Bridge yielded similar results, yet with smaller R2