Skip to main content
. 2013 Jan 28;26(4):299–305. doi: 10.1093/protein/gzs105

Table I.

Steady-state kinetic parameters for protein degradation and ATP hydrolysis by E.coli Lon. The error is that of non-linear-least-squares fitting. ATP per substrate was calculated by dividing Vmax for ATP hydrolysis by Vmax for protein degradation

Substrate Proteolysis Vmax (min−1 Lon6−1) Proteolysis apparent KM (µM) Proteolysis Hill constant ATPase Vmax (min−1 Lon6−1) ATPase apparent KM (µM) ATPase Hill constant ATP per substrate
cp6-sul20 3.6 ± 0.2 13 ± 2 1.2 ± 0.1 217 ± 16 9.3 ± 1.3 1.2 ± 0.1 60
β20-cp6 2.3 ± 0.3 21 ± 6 1.2 ± 0.2 143 ± 5 2.6 ± 0.2 1.7 ± 0.1 62
cp7-sul20 0.70 ± 0.03 2.8 ± 0.3 1.6 ± 0.3 130 ± 22 5.2 ± 2.4 0.9 ± 0.2 186
β20-cp7 1.2 ± 0.1 8 ± 1 1.6 ± 0.3 130 ± 14 4.8 ± 1.0 1.3 ± 0.2 108
cp6-Δ8-sul20 3.3 ± 0.1 13 ± 1 1.4 ± 0.1 215 ± 50 6.0 ± 3.0 1.1 ± 0.3 65