Skip to main content
. Author manuscript; available in PMC: 2014 Jun 27.
Published in final edited form as: J Med Chem. 2013 Jun 13;56(12):5059–5070. doi: 10.1021/jm400369q

Table 2.

Michaelis-Menten kinetics of Spectrozyme TH hydrolysis by α-thrombin in the presence of the trimer 9a.a

[9a] (μM) Overnight incubation at 25°C 2 hr incubation at 37°C
KM (μM) VMAX (mAU/min) KM (μM) VMAX (mAU/min)


0 9.5 ± 1.8b 81 ± 5 7.7 ± 2.0 86 ± 7
0.36 11.1 ± 2.5 80 ± 6 c
0.63 7.7 ± 1.3 69 ± 3 6.7 ± 2.3 72 ± 8
1.53 2.2 ± 0.8 30 ± 2
1.80 3.2 ± 0.5 35 ± 1
3.60 3.1 ± 0.60 19 ± 1 2.7 ± 0.6 25 ± 1
9.90 1.9 ± 0.6 15 ± 0.8
a

KM and VMAX were measured by monitoring the initial rate of thrombin hydrolysis of Spectrozyme TH (2 – 80 μM) from the linear increase in absorbance at 405 nm in the presence of fixed concentration of 9a that was incubated either overnight at 25°C or for two hours at 37°C in 20 mM Tris-HCl buffer, pH 7.4, containing 100 mM NaCl, 2.5 mM CaCl2 and 0.1 % PEG8000. The data was fitted by the standard Michaelis – Menten equation to obtain KM and VMAX, as described in ‘Experimental Procedures’.

b

Error represents ±1 S.E.

c

Not measured