Thrombus Diagnosis by Routine Echo and Cine-CMR

Sensitivity Specificity Accuracy Positive
Predictive
Value
Negative
Predictive
Value
Echo (overall) 33% (8/24) 91% (199/219) 85% (207/243) 29% (8/28) 93% (199/215)
  Clinical Indication LV Thrombus 60% (3/5) 88% (7/8) 77% (10/13) 75% (3/4) 78% (7/9)
Other* 26% (5/19) 91% (192/211) 86% (197/230) 21% (5/24) 93% (192/206)
Cine-CMR (overall) 58% (14/24) 99% (218/219) 95% (232/243) 93% (14/15) 96% (218/228)
*