Table 2.
Sensitivity | Specificity | Accuracy | Positive Predictive Value |
Negative Predictive Value |
||
---|---|---|---|---|---|---|
Echo (overall) | 33% (8/24) | 91% (199/219) | 85% (207/243) | 29% (8/28) | 93% (199/215) | |
Clinical Indication | LV Thrombus | 60% (3/5) | 88% (7/8) | 77% (10/13) | 75% (3/4) | 78% (7/9) |
Other* | 26% (5/19) | 91% (192/211) | 86% (197/230) | 21% (5/24) | 93% (192/206) | |
Cine-CMR (overall) | 58% (14/24) | 99% (218/219) | 95% (232/243) | 93% (14/15) | 96% (218/228) |
Excluding patients with echo done for stated indication of possible LV thrombus assessment (n=13).