Incinerator County Permitted throughput (tonnes/year) Flue Stack height (m) Stack diameter (m) Flue exit flow rate (m3/s) Flue exit velocity (m/s) Temperature (°C)
Crymlyn Burrows Neath Port Talbot (South Wales) 52,500 1 40 0.95 12.3 17.6 136
Marchwood Hampshire (England) 210,000 1
2
65
65
1.25
1.25
30.3
30.9
24.7
25.2
150
148

Flue exit flow rate, velocity, and temperature for Crymlyn Burrows provided are a mean of biannual measurements for most years of operation, whereas for Marchwood these measures are single measures derived from the permit application.