Table 2.

IOL decentration and tilt obtained from the image with different scanned angle.

Scanned angle/° Tilt/° Decentration/mm
Case  6 Case  4 Case  12 Case  6 Case  4 Case  12
Surface fitting AS-OCT Surface fitting AS-OCT Surface fitting AS-OCT Surface fitting AS-OCT Surface fitting AS-OCT Surface fitting AS-OCT
0 2.72 3.60 2.21 2.50 3.60 4.20 0.18 1.86 0.15 0.01 0.03
15 3.93 1.50 1.70 3.40 4.20 3.50 0.68 1.69 0.35 0.85 0.13 0.68
30 3.82 1.90 1.47 4.10 4.50 5.40 0.44 1.39 0.52 0.79 0.29 0.74
45 3.41 3.20 1.21 2.00 4.53 4.10 0.17 1.32 0.66 0.78 0.42 0.31
60 2.83 1.30 0.40 0.50 4.21 3.60 0.11 2.40 0.75 0.33 0.53 0.28
75 2.03 4.20 0.30 0.50 3.64 2.90 0.38 1.67 0.80 0.67 0.60 0.21
90 1.1 2.00 0.92 1.60 2.79 2.10 0.63 2.16 0.78 0.16 0.63 0.03
105 0.04 0.00 1.40 1.00 1.77 1.20 0.83 2.34 0.72 0.59 0.62 0.07
120 0.98 2.40 1.85 2.10 0.62 0.00 0.98 2.34 0.61 0.31 0.56 0.42
135 1.13 3.10 2.21 2.70 0.59 0.00 0.87 0.45 0.03 0.47 0.03
150 2.74 2.40 2.40 3.50 1.74 1.20 1.07 1.94 0.26 0.03 0.34 0.24
165 3.38 2.30 2.35 4.90 2.76 3.50 1.01 1.77 0.06 0.77 0.20 0.32
IOL 3.92 4.20 2.37 4.90 4.55 5.40 1.08 2.40 0.80 0.85 0.63 0.74