Skip to main content
. 2013 Jul 18;13:20. doi: 10.1186/1471-2342-13-20

Table 2.

Comparison of SNR from the normal brain for SE, GE and GEFC pulse sequences pre, and at the respective time points: 20, 120 min and 24 hrs for SE; 30, 130 min and 24 hrs for GE; 31, 131 min and 24 hrs for GEFC post iv tail injection of the targeted contrast agent

  Pre 20/30/31 min 120/130/131 min 24 hrs
SE
25.3
19.7
25.9
26.2
GE
29.0
18.7
24.5
25.4
GEFC 31.2 21.1 25.9 29.8

The standard deviation was smaller than ±1.3 for each measurement. The SNR for GE is corrected for the bandwidth difference (0.8).