Abstract
The 16th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance (SCMR) took place in San Francisco, USA at the end of January 2013. With a faculty of experts from across the world, this congress provided a wealth of insight into cutting-edge research and technological development. This review article intends to provide a highlight of what represented the most significant advances in the field of cardiovascular magnetic resonance (CMR) during this year’s meeting.
Keywords: Cardiovascular magnetic resonance, Heart
Introduction
This year’s SCMR Annual Scientific Sessions were attended by a record number of 1427participants. The number of abstracts presented during the meeting also grew significantly from previous editions with a total of 602 abstracts being shown. Many of these new abstracts were introduced during the SCMR/International Society for Magnetic Resonance in Medicine (ISMRM) Jointly Sponsored Workshop “New Horizons in High-field Cardiovascular Imaging: Promises and Progress” as well as in the new ePosterGallery.
In this article, we have tried to cover most of the themes presented during the five days of the event summarizing the topics into technical/imaging methods and clinical applications. Throughout the meeting, the SCMR Program Committee ensured that all of the major areas of interest were covered with an invited lecture session to complement the scientific abstract presentations. All abstracts presented during the meeting can be accessed in the special supplement of the Journal of Cardiovascular Magnetic Resonance [1]. Many of the invited lectures and oral abstract sessions were recorded and are available at http://www.scmr.org.
Review
Details of the SCMR Gold Medal award for outstanding contribution to the field of CMR (awarded to Professor Stefan Neubauer), the best oral presentations and abstract award winners for both SCMR annual scientific sessions and the SCMR/ISMRM workshop are given in Tables 1 and 2. The winning authors of the Gerald Pohost award for best Journal of Cardiovascular Magnetic Resonance (JCMR) manuscript in 2012 are shown in Table 3.
Table 1.
Award | Recipient | Institution | Subject |
---|---|---|---|
SCMR Gold Medal |
Professor Stefan Neubauer |
Oxford University |
For outstanding contribution to the field of CMR |
Early career award – basic science |
Behzad Sharif |
Cedars-Sinai Medical Center |
Eliminating dark-rim artifacts in first-pass myocardial perfusion imaging (O3) |
Early career award – translational |
James Harrison |
King’sCollege London |
Magnetic resonance imaging of acute and chronic atrial ablation injury – a histological validation study (O18) |
Early career award – clinical |
Saira Dass |
The John Radcliffe Hospital |
Patients with dilated cardiomyopathy (DCM) have appropriate myocardial oxygenation response to vasodilator stress (O68) |
Moderated poster session 1 |
Kathryn Broadhouse |
Imperial College London |
Quantification of aortic pulse wave velocity in preterm infants using 4D phase contrast MRI (M7) |
Moderated postersession 2 |
Daniel Kuetting |
Universityof Bonn |
Assessment of cardiac dyssynchrony: a comparison of velocity encoded imaging and feature tracking analysis (M11) |
Best technologist abstract |
Celia O’Meara |
UniversityCollege London Hospitals |
Initial experience of imaging cardiac sarcoidosis using hybrid PET-MR – a technologist’s case study (T1) |
Best SCMR web case of the year | Rob Huggett | Russells Hall Hospital, UK | Post pericardiectomy for constriction – a late complication |
Table 2.
Award | Recipient | Institution | Manuscript title |
---|---|---|---|
Best Oral Abstract |
Gabriel Camargo |
Clinica de Diagnostico por Imagem, Rio de Janeiro, Brazil |
Myocardial Iron Quantification Using Modified Look-Locker Inversion Recovery (MOLLI) T1 Mapping at 3 Tesla |
Best Poster | Johannes Krug | Otto-von-Guericke University of Magdeburg | Improved ECG Based Gating in Ultra High Field Cardiac MRI Using an Independent Component Analysis Approach |
Table 3.
Award | Recipient | Institution | Manuscript title |
---|---|---|---|
First place |
Jurg Schwitter |
University Hospital, Lausanne |
Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial). [2] |
Second place |
Peter Kellman |
National Institutes of Health (NIH) |
Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method. [3] |
Third place | Choukri Mekkaoui | Harvard Medical School | Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation. [4] |
Technical advances/imaging methods
This year’s SCMR/ISMRM pre-Sessions workshop focused on the development of high-field CMR, an increasing area of interest as scanners move from 1.5 T to 3.0 T and even 7.0 T systems [5,6]. Challenging problems with high field strengths currently involve the development of specific transmit/receive coils to allow assessment of 23Na-MRI as well as CMR-spectroscopy, new imaging sequences to take advantage of the increase in signal-to-noise ratio (SNR) as well as better ways to handle ECG gating. In that regard, Ferreira et al. presented a new free-breathing navigator sequence to assess cardiac diffusion tensor imaging (DTI) at 3 T to characterize myocardial fiber disarray patterns as has recently been published [7-9] while Teh et al. demonstrated a new accelerated diffusion-weighted fast spin echo sequence that resulted in an 8-fold increase in acquisition time in a mouse model using 9.4 T scanning [10]. DTI was the subject of one of three plenary lectures delivered by Dudley Pennell at the opening of the main meeting (http://scmr.org/Education/CMR-online-video-on-demand-lectures/3072/3248/3252.html) – Figure 1. As mentioned above, ECG gating becomes more difficult with increasing field strength due to magnetohydrodynamic effects of the higher magnetic fields. To circumvent that problem, Krug et al. demonstrated the problems encountered with regular vectorcardiograms at 3.0 and 7.0 T proposing an independent component analysis alternative [11] and Tse et al. presented a new 3D-QRS method using 12-lead ECG gating inside the magnet to allow for real-time gating at 3.0 T in patients with complex heart rates such as premature ventricular beats, atrial fibrillation and significant beat-to-beat variations [12].
Increasing spatial/temporal resolution
Many advances presented this year dealt with technical developments with the objective of increasing the spatial and/or temporal resolution of CMR images as well as decreasing image acquisition time. One major focus was how to implement new methods in order to acquire real-time non triggered images allowing much more simple and robust imaging as well as permitting the use of CMR to guide percutaneous interventions [13]. Aneja et al. demonstrated that real-time CMR using non-optimized sequences with lower spatial and temporal resolution already derives similar results to traditional breath-held images in patients with regular cardiac rhythm [14]. Although this approach was limited to a small number of patients and using standard sequences only, the principles of real-time imaging are rapidly gaining acceptance as CMR increases its clinical utility.
With that objective in mind, an increasing number of abstracts focused on new sequences that take advantage of undersampling the k-space with spatiotemporal modeling such as compressed sensing [15] to increase current resolution limits. Using sparse and incoherent sampling with multiple iterative reconstructions Schmidt et al. showed that these new techniques provide high spatial (2.4 × 1.7 × 6.0 mm) as well as temporal resolution (33 ms) within 1 heartbeat acquisition in real time [16]. Introducing a new regional sparsity reconstruction method, Chen et al. also demonstrated the feasibility of compressed sensing for obtaining in vivo perfusion images, allowing for increase in ventricular coverage or spatial resolution as previous techniques have shown [17,18].
Non-cartesian acquisitions have also seen a gain in use and moved from the preliminary work in coronary artery imaging to other applications in CMR [19]. Sharif et al. used an ungated radial acquisition method to acquire first-pass perfusion images simultaneously combined with cine images for assessment of perfusion and wall motion within the same scan [20]. Yang et al. also used a combination of spiral trajectories with compressed sensing to obtain full ventricular coverage during first pass perfusion with the acquisition of 8 slices in 480 ms with 1.75 × 1.75 mm in-plane resolution allowing for heart rates up to 125 beats per minute during stress imaging [21]. In another abstract by Petersson et al. the authors demonstrated the use of spiral k-space trajectories to acquire 4D flow stacks with a significant 62% reduction in scan time while maintaining similar image quality compared to traditional readout methods [22].
Improving artifacts
Another highlight of the meeting was in the developments of new methods to overcome old problems in CMR such as dark rim artifacts, off-resonance effects and banding [23]. The Early Career Award in Basic Sciences was awarded to Sharif et al. for an abstract that proposed to reduce dark-rim artifacts during first-pass perfusion by using a single-shot radial sequence in comparison to the routine Cartesian technique with a significant decrease in both artifact score as well as in its maximum width (Figure 2) [24]. Problems with 3 T MRI were also addressed by Wu et al. who proposed a shorter TR for SSFP cine imaging through a reduced RF pulse duration and readout showing that the new approach resulted in images more robust to field in homogeneity at this higher field strength with minimum reduction in spatial resolution while allowing for elimination of frequency scouts and more rapid breath-hold times [25]. Another way to improve susceptibility artifacts without the need to use time consuming frequency adjustments was presented by Rothstein et al. who proposed a new 3D shimming algorithm which resulted in similar results for volumes and function evaluation keeping the same levels of banding artifacts as frequency offsets but with a more simplified workflow [26].
T1 Mapping sequence developments
With the rapidly increasing body of new clinical data on T1 mapping, more understanding of the fundamental principles of the sequences used to generate these maps is essential [27]. A comprehensive series of lectures on T1 mapping in the heart was presented by Peter Kellman, Martin Ugander, Erica Dall’ Armellina and Andrew Flett (http://scmr.org/Education/CMR-online-video-on-demand-lectures/3072/3151/3154.html).This provided a clear explanation of the pros and cons of each of the different sequences together with the importance of both accuracy and precision of measurement. The potential clinical applications of T1 mapping including the measurement of extracellular volume fraction to visualize the extent and severity of abnormalities within the myocardium were outlined in detail.
Almost 10% of the submitted abstracts for the meeting involved T1 mapping. Many sessions discussed the current use of T1 maps and the need to standardize and optimize the acquisition techniques to pre- and post-contrast maps, the use of bolus versus continuous infusion of gadolinium as well as the different approaches to heart rate variability and types of sequences. Fitts et al. presented a recent arrhythmia-insensitive rapid T1 mapping sequence to overcome some of the limitations of the most widely used modified Look-Locker inversion recovery (MOLLI) techniques [28]. The sequence is based on saturation recovery magnetization and uses centric k-space ordering resulting in smaller coefficients of variation and higher T1 values in patients with high heart rates or arrhythmias. In another study using phantoms, Slavin et al. also showed that using a saturation recovery pulse but with a balanced SSFP readout they could find more accurate T1 values compared to MOLLI due to its insensitivity to beat-to-beat variations and lack of T2 dependence [29]. In a comparison of different sequences including the classical MOLLI sequence, a shortened (sh)MOLLI acquisition with 9 heartbeats [30], a 3′5 MOLLI and a saturation recovery single shot acquisition sequence (SASHA) the authors reported that the 3′5 MOLLI sequence was more closely associated to the original MOLLI T1 values compared to the two other sequences while the shMOLLI technique underestimated T1 values by 13% and the SASHA sequence overestimated the T1 values by 17%. Finally, a 3D technique acquired with free breathing was also presented by Henningsson et al. with the average scan time of 9:37 minutes to cover the whole left ventricle with a resolution of 1.5 × 1.5 × 8 mm3 using SASHA resulting in an increase in SNR compared to 2D-SASHA images with similar T1 values [31].
Developments in vascular imaging
The development of rapid prototyping (or 3D printing) has allowed highly accurate models of vascular structures to be generated [32]. Acevedo-Bolton et al. described how complex intracranial aneurysms imaged with magnetic resonance could be recreated in order to test the effectiveness of flow-diverting stents [33]. This work not only enables the operator to gain valuable experience on a ‘dry run’ but allows assessment of the pre- and post-procedure flow dynamics using 4D flow.
Three other oral presentations described the utility of the quiescent-interval single shot or ‘QISS’ sequence for non-contrast MR angiography. The technique (with various alterations including radial vs. Cartesian geometry k-space acquisition) shows excellent performance and correlates very well with contrast exams in patients with peripheral arterial disease. These angiographic techniques have the potential to be combined with more functional assessment (such as rest and stress calf perfusion) to assess ischemia and response to treatment [34]. Clement-Guinaudeauet al presented data on a calf muscle perfusion index which correlated very well with peak walking time and claudication onset time [35]. Using a simple MR-compatible device to allow exercise stress in the scanner bore, this has useful potential as a surrogate endpoint for clinical trials.
Implementation of CMR into routine clinical practice
In addition to many technical developments, this year’s SCMR also featured several presentations showing the central role of CMR in the management of the cardiovascular patient. One of the strengths of this year’s conference was the introductory talk given by an expert in the field at the start of each of the oral abstract sessions. Raymond Kwong succinctly summarized the available evidence from the last 25 years on how the development of CMR has helped diagnosis, determine prognosis and provide an impact on diagnostic thinking, therapeutic actions and patient outcomes. Anya Wagner presented the most recent results of the EuroCMR registry covering 27,000 patients from 57 European centers [36]. This has cemented CMR at the center of diagnostic imaging in Europe, proving that it is feasible and safe with 62% of the scans performed having an impact on patient management, the most common indication being for risk stratification in coronary artery disease. Florian Andre presented data from a cohort of more than a 1000 patients showing that measuring left ventricular ejection fraction by CMR reclassified many patients into different risk groups when compared to echocardiography [37]. Others have shown the potential clinical impact of more accurate measurement of ejection fraction by CMR on selecting patients who might benefit from defibrillator implantation [38]. Recently, it has been demonstrated that the addition of late gadolinium enhancement CMR adds further prognostic value over echocardiography alone [39]. Additionally, it is becoming increasingly recognized that using CMR in a cost-effective way can provide potential savings for healthcare providers [40].
Ischemic heart disease
With the publication of CE-MARC [41] and MR-IMPACT 2 [2] vasodilator stress CMR has been shown in prospectively designed studies to be a reasonable alternative to stress single-photon emission computed tomography (SPECT) for the detection of significant coronary artery disease. It has additionally been shown that performing stress CMR to identify patients who benefit from coronary angiography offers significant savings when compared to directly performing coronary angiography. John Greenwood adds to this by presenting new data from the CE-MARC trial suggesting that strategies the utilize stress CMR first followed by invasive coronary angiography if the CMR study is abnormal or inconclusive may be more cost-effective when compared to a SPECT first strategy [42]. Similarly, Sebastian Kelle showed the cost-effectiveness of strategies for the assessment of stable coronary artery disease that utilize dobutamine stress to identify patients who might benefit from a coronary angiogram rather than sending all patients directly to cardiac catheterization [43]. Using a Markov analysis, Steffen Petersen presented data suggesting that the cost-effectiveness of a diagnostic strategy was dependent on the pretest probability of having coronary artery disease. His analysis suggested stress CMR strategies were most cost effective in patients with a higher pretest probability and that cardiac computed tomography strategies were more cost-effective in patients with a low to intermediate pretest probability [44].
An important limitation of stress CMR is the incomplete coverage of the left ventricle and may prevent adequate assessment of ischemic burden. Sven Plein compared the ischemic and scar burden as determined by a standard clinical stress CMR technique to SPECT [45]. He found that CMR measures significantly less scar but more ischemia than SPECT possibly due to the incomplete coverage of perfusion CMR. In a prospective, multicenter trial, Robert Manka showed that whole heart, three-dimensional myocardial perfusion imaging (Figure 3) correlated highly with fractional flow reserve [46].It remains to be seen whether such a technique will improve the quantification of ischemic burden and whether the burden of ischemia as measured by CMR can identify patients who will benefit from revascularization in addition to aggressive medical therapy alone.
Non-ischemic heart disease
The role of CMR in the assessment and risk stratification of non-ischemic heart disease is well established [47]. Currently available data detail the ability of CMR to risk stratify patients with a variety of non-ischemic heart diseases such as dilated cardiomyopathy, myocardial siderosis, and hypertrophic cardiomyopathy (HCM) [48]. However, large outcome studies remain challenging. Ismail et al. presented data on 711 consecutive patients with HCM with a total of 2852 patient-years of follow-up [49]. Although the amount of fibrosis was a significant univariate predictor of sudden cardiac death risk, on multivariate analysis, only left ventricular ejection fraction remained a significant predictor. The understanding of the HCM phenotype is becoming ever more complex [48,50]. Deva explained the incremental predictive value of inferoseptal crypts [51] and Flett proposed a previously unrecognized pattern of relative apical hypertrophy which may be an early form of HCM as the group found many features of HCM in patients with unexplained T-wave inversion [52]. Christopher Kramer unveiled the details of a proposed large scale, multiparametric, multicenter, observational registry with the goal of better defining the role of CMR in the risk stratification of the HCM patient.
As previously mentioned, T1 mapping featured highly throughout the sessions. Sado et al. presented findings of low pre-contrast T1 values in Anderson-Fabry disease and iron overload which may help to define pre-clinical phenotypes more accurately [53]. Whereas the assessment of diastolic function has traditionally been cumbersome and time-consuming with CMR, Simpson et al. have developed a new high spatial and temporal resolution tissue phase contrast technique which allows much shorter acquisitions and brings this nearer to clinical prime-time [54]. In an invited lecture, Michael Markl reviewed promising techniques such as tissue phase mapping with respiratory navigator gating, 2-dimensional and 3-dimensional Displacement Encoding with Stimulated Echoes (DENSE), and strain encoded imaging (SENC) for assessing myocardial mechanics and quantifying the various components of myocardial strain (http://scmr.org/Education/CMR-online-video-on-demand-lectures/3072/3157/3160.html). During the same session, Alicia Maceira, Amit Patel, and Sophie Mavrogeni suggested that CMR with late gadolinium enhancement imaging plays an important role for the detection of cardiac involvement and risk stratification of patients with systemic disorders such as amyloidosis, vasculitis, and other rheumatologic disorders such as systemic lupus erythematosis, sarcoidosis, rheumatoid arthritis, and systemic sclerosis (http://scmr.org/Education/CMR-online-video-on-demand-lectures/3072/3157/3161.html).
CMR and electrophysiology
Francisco Leyva reviewed the role of CMR for identifying patients that may benefit from defibrillator implantation and resynchronization therapy (http://scmr.org/Education/CMR-online-video-on-demand-lectures/3072/3163/3164.html). Several investigators have shown that the extent of late gadolinium enhancement is strongly associated with need for future ICD therapy [55]. The burden of late gadolinium enhancement is also associated with likelihood of responding to resynchronization therapy; in fact, using late gadolinium enhancement images to guide left ventricular lead placement improves outcomes following biventricular pacing [56].
The continued development of real-time imaging for interventional CMR procedures is an important area of research. Tse et al presented preliminary animal data on a voltage-based electroanatomic tracking system which can be used to measure intracardiac electrograms both in and out of the scanner bore, including during imaging sequences. Radiofrequency signals from patches on the skin allow the operator to track the navigation of a catheter tip without the need for co-registration [57]. Ramanan et al. went on to describe how catheter ablation lesions could be mapped acutely using a combination of T2 and T1* mapping with late gadolinium enhancement [58]. This has the potential for verifying the effectiveness of ablation by differentiating the actual lesion area from surrounding oedema. On a different subject, Ainslie et al. reported interim data from the multiparametric CMR assessment on RV apical versus septal pacing study (MAPS)which aims to determine the optimal site for right ventricular pacing using CMR, echo, cardiopulmonary exercise testing and biomarkers [59]. Patients with persistent atrial fibrillation requiring AV node ablation and permanent pacemaker implants were fitted with an MR-conditional St. Jude pacemaker and two RV endocardial leads placed at the RV apex and in the septum (one in the ventricular port and one in the atrial port of the device). Using a crossover study design with ventricular pacing at each of the sites, CMR measurements were taken at three time points. Early results have shown that not only is cardiac scanning safe in these patients but that there is higher aortic and pulmonary flow as well as less dyssynchrony with septal pacing.
Congenital heart disease
CMR continues to show its superiority over other imaging modalities in the field of congenital cardiovascular disease. This year cases for one of the congenital heart case review sessions were competitively selected from open competition with blind and independent ratings from several expert reviewers. The resultant session was popular, interactive and of high quality. The benefits of CMR in congenital heart disease, not least with regards accurate anatomical delineation, were well illustrated. In addition, refinements in flow imaging are improving our understanding not only in complex congenital disease but also in more routine cases. Muzzarelli et al. presented their data on the optimal measurement of aortic flow in bicuspid aortic valve disease [60] and Hart et al. demonstrated how 4D flow can give a much greater insight into the understanding of haemodynamics of the Fontan circulation during the breathing cycle [61]. Although acquisitions can be long and complex post-processing is required, 4D flow techniques have the potential to develop into a useful clinical tool [62].
Case presentations
As in previous years, a highly popular component of the program involved a series of 10 case review sessions, each discussing a range of interesting cases including complex, challenging problems and more mundane day-to-day cases. A lively, interactive debate was generated between delegates and experts in the field. The SCMR website publishes a regular featured ‘case of the week’ and the best 5 of these cases from 2012 were presented in full (http://scmr.org/caseoftheweek.html).
Conclusions
In conclusion, the 2013 SCMR Scientific Sessions has consolidated a now long track record of successful meetings positioning CMR as a robust and prominent option in cardiovascular imaging. The technical advances highlighted here and the clinical applications ready to be implemented in daily routine presented at the meeting demonstrate that the method has never been so relevant and promising, with a continuous increase in the number of manuscripts published as well as a rising number of practitioners. SCMR deserves much recognition for this accomplishment and its meeting is certainly a reflection of that success.
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
JLF conceived the study and participated in the design, data collection and draft of the manuscript. JPC and ARP participated in the design, data collection and draft of the manuscript. All authors read and approved the final manuscript.
Contributor Information
John-Paul Carpenter, Email: j.carpenter@rbht.nhs.uk.
Amit R Patel, Email: apatel2@medicine.bsd.uchicago.edu.
Juliano Lara Fernandes, Email: jlaraf@terra.com.br.
References
- Pennell DJ. Abstracts of the 16th annual SCMR scientific sessions. J Cardiovasc Magn Reson. 2013;15(Suppl 1):1–481. doi: 10.1186/1532-429X-18-S1-O33. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schonberg SO, Debl K, Strohm O, Ahlstrom H. et al. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: the secondary endpoints of the multicenter multivendor MR-IMPACT II (magnetic resonance imaging for myocardial perfusion assessment in coronary artery disease trial) J Cardiovasc Magn Reson. 2012;14:61. doi: 10.1186/1532-429X-14-61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kellman P, Wilson JR, Xue H, Ugander M, Arai AE. Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method. J Cardiovasc Magn Reson. 2012;14:63. doi: 10.1186/1532-429X-14-63. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mekkaoui C, Huang S, Chen HH, Dai G, Reese TG, Kostis WJ, Thiagalingam A, Maurovich-Horvat P, Ruskin JN, Hoffmann U. et al. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation. J Cardiovasc Magn Reson. 2012;14:70. doi: 10.1186/1532-429X-14-70. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Oshinski JN, Delfino JG, Sharma P, Gharib AM, Pettigrew RI. Cardiovascular magnetic resonance at 3.0 T: current state of the art. J Cardiovasc Magn Reson. 2010;12:55. doi: 10.1186/1532-429X-12-55. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snyder CJ, DelaBarre L, Metzger GJ, van de Moortele PF, Akgun C, Ugurbil K, Vaughan JT. Initial results of cardiac imaging at 7 Tesla. Magn Reson Med. 2009;61:517–24. doi: 10.1002/mrm.21895. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R. et al. In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med. 2012;12:17. doi: 10.1002/mrm.24488. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McGill LA, Ismail TF, Nielles-Vallespin S, Ferreira P, Scott AD, Roughton M, Kilner PJ, Ho SY, McCarthy KP, Gatehouse PD. et al. Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2012;14:86. doi: 10.1186/1532-429X-14-86. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ferreira PJ, Nielles-Vallespin S, Gatehouse PD, de Silva R, Keegan J, Speier P, Feiweier T, Reese TG, Ismail TF, Scott A. et al. Cardiac diffusion tensor imaging: helix angle (HA) healthy statistical average technique for HA quantification in vivo. J Cardiovasc Magn Reson. 2013;15(suppl 1):W7. [Google Scholar]
- Teh I, Lohezic M, Aksentijevic D, Schneider JE. Accelerated fast spin echo diffusion spectrum imaging in the mouse heart ex-vivo. J Cardiovasc Magn Reson. 2013;15(suppl 1):W6. doi: 10.1186/1532-429X-15-S1-W6. [DOI] [Google Scholar]
- Krug JW, Rose G, Stucht D, Clifford G, Oster J. Limitations of VCG based gating methods in ultra high field cardiac MRI. J Cardiovasc Magn Reson. 2013;15(suppl 1):W19. doi: 10.1186/1532-429X-15-S1-W19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tse Z, Dumoulin C, Watkins R, Butts Pauly K, Kwong RY, Michaud GF, Stevenson W, Joslesz F, Schmidt EJ. Improved cardiac gating at 3T with the “3D-QRS” method utilizing MRIcompatible 12-lead ECGs. J Cardiovasc Magn Reson. 2013;15(suppl 1):W20. doi: 10.1186/1532-429X-15-S1-E20. [DOI] [Google Scholar]
- Kahlert P, Parohl N, Albert J, Schafer L, Reinhardt R, Kaiser GM, McDougall I, Decker B, Plicht B, Erbel R. et al. Real-time magnetic resonance imaging-guided transarterial aortic valve implantation: in vivo evaluation in swine. J Am Coll Cardiol. 2012;59:192–3. doi: 10.1016/j.jacc.2011.09.046. [DOI] [PubMed] [Google Scholar]
- Aneja A, Ono C, Scandling D, Jin N, Hinton AM, Pennell M, Raman SV, Simonetti OP. Left ventricular function, aortic velocity, and late gadolinium enhancement assessed by real-time and single shot CMR is comparable to breath-held segmented imaging: a prospective study. J Cardiovasc Magn Reson. 2013;15(suppl 1):O51. doi: 10.1186/1532-429X-15-S1-O51. [DOI] [Google Scholar]
- Gamper U, Boesiger P, Kozerke S. Compressed sensing in dynamic MRI. Magn Reson Med. 2008;59:365–73. doi: 10.1002/mrm.21477. [DOI] [PubMed] [Google Scholar]
- Schmidt M, Ekinci O, Liu J, Lefebvre A, Nadar MS, Mueller E, Zenge MO. Novel highly accelerated real-time CINE-MRI featuring compressed sensing with k-t regularization in comparison to TSENSE segmented and real-time Cine imaging. J Cardiovasc Magn Reson. 2013;15(suppl 1):P36. doi: 10.1186/1532-429X-15-S1-P36. [DOI] [Google Scholar]
- Jogiya R, Kozerke S, Morton G, De Silva K, Redwood S, Perera D, Nagel E, Plein S. Validation of dynamic 3-dimensional whole heart magnetic resonance myocardial perfusion imaging against fractional flow reserve for the detection of significant coronary artery disease. J Am Coll Cardiol. 2012;60:756–65. doi: 10.1016/j.jacc.2012.02.075. [DOI] [PubMed] [Google Scholar]
- Chen X, Salerno M, Epstein FH. Accelerated first-pass perfusion CMR using compressed sensing with regional spatiotemporal sparsity. J Cardiovasc Magn Reson. 2013;15(suppl 1):E16. [Google Scholar]
- Tsao J. Ultrafast imaging: principles, pitfalls, solutions, and applications. J Magn Reson Imaging. 2010;32:252–66. doi: 10.1002/jmri.22239. [DOI] [PubMed] [Google Scholar]
- Sharif B, Dharmakumar R, Arsanjani R, Thomson LE, Merz NB, Berman DS, Li D. Ungated cine first-pass CMR for concurrent imaging of myocardial perfusion defects and wall motion abnormalities. J Cardiovasc Magn Reson. 2013;15(suppl 1):O1. doi: 10.1186/1532-429X-15-S1-O1. [DOI] [Google Scholar]
- Yang Y, Feng X, Meyer CH, Kramer CM, Salerno M. First-pass myocardial perfusion imaging with whole ventricular coverage using L1-SPIRIT accelerated spiral trajectories. J Cardiovasc Magn Reson. 2013;15(suppl 1):P20. doi: 10.1186/1532-429X-15-S1-E20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Petersson S, Sigfridsson A, Carlhall CJ, Ebbers T. Retrospectively gated intra-cardiac 4D flow CMR using spiral k-space trajectories. J Cardiovasc Magn Reson. 2013;15(supll 1):O64. [Google Scholar]
- Biglands JD, Radjenovic A, Ridgway JP. Cardiovascular magnetic resonance physics for clinicians: part II. J Cardiovasc Magn Reson. 2012;14:66. doi: 10.1186/1532-429X-14-66. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sharif B, Dharmakumar R, LaBounty T, Shufelt C, Thomson LE, Merz NB, Berman DS, Li D. Eliminating dark-rim artifacts in first-pass myocardial perfusion imaging. J Cardiovasc Magn Reson. 2013;15(suppl 1):O3. doi: 10.1002/mrm.24913. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wu Y, Yang F, Chung Y-C. Robust and fast SSFP for the evaluation of LV function at 3T. J Cardiovasc Magn Reson. 2013;15(suppl 1):O52. doi: 10.1186/1532-429X-15-S1-E52. [DOI] [Google Scholar]
- Rothstein T, Camargo GC, Quintella DC, Fernandes E, Strecker R, Greiser A, Derenne ME, Lima M, Moojen JJ, Rizzi PB. et al. Artifact suppression of SSFP cine sequences at 3T using a novel automatic 3D shimming algorithm. J Cardiovasc Magn Reson. 2013;15(suppl 1):P57. doi: 10.1186/1532-429X-15-S1-E57. [DOI] [Google Scholar]
- White SK, Sado DM, Flett AS, Moon JC. Characterising the myocardial interstitial space: the clinical relevance of non-invasive imaging. Heart. 2012;98:773–9. doi: 10.1136/heartjnl-2011-301515. [DOI] [PubMed] [Google Scholar]
- Fitts M, Breton E, Kholmovski E, Dosdall DJ, Vijayakumar S, Hong KP, Ranjan R, Marrouche NF, Axel L, Kim D. Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence. J Cardiovasc Magn Reson. 2013;15(suppl 1):O112. doi: 10.1186/1532-429X-15-S1-O112. [DOI] [PubMed] [Google Scholar]
- Slavin GS, Stainsby JA. True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI. J Cardiovasc Magn Reson. 2013;15(suppl 1):P3. [Google Scholar]
- Piechnik SK, Ferreira VM, Dall’Armellina E, Cochlin LE, Greiser A, Neubauer S, Robson MD. Shortened modified look-locker inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 And 3 T within a 9 heartbeat breathhold. J Cardiovasc Magn Reson. 2010;12:69. doi: 10.1186/1532-429X-12-69. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Henningsson M, Botnar RM, Voigt T. 3D saturation recovery imaging for free breathing myocardial T1 mapping. J Cardiovasc Magn Reson. 2013;15(suppl 1):P44. [Google Scholar]
- Biglino G, Verschueren P, Zegels R, Taylor AM, Schievano S. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing. J Cardiovasc Magn Reson. 2013;15:2. doi: 10.1186/1532-429X-15-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Acevedo-Bolton G, Saloner D. Using MRI derived patient-specific flow models and flow imaging for flow diverting stent rehearsal. J Cardiovasc Magn Reson. 2013;15(suppl 1):O56. [Google Scholar]
- Jiji RS, Pollak AW, Epstein FH, Antkowiak PF, Meyer CH, Weltman AL, Lopez D, Dimaria JM, Hunter JR, Christopher JM, Kramer CM. Reproducibility of rest and exercise stress contrast-enhanced calf perfusion magnetic resonance imaging in peripheral arterial disease. J Cardiovasc Magn Reson. 2013;15:14. doi: 10.1186/1532-429X-15-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Clement-Guinaudeau S, Topel ML, Ali A, Poole JC, Rocco E, Khan SA, Zhong X, Epstein FH, Kramer CM, Quyyumi AA, Oshinski JN. MR-based calf muscle perfusion index correlates with treadmill exercise test parameters in patients with peripheral arterial disease. J Cardiovasc Magn Reson. 2013;15(suppl 1):O58. doi: 10.1186/1532-429X-15-S1-P58. [DOI] [Google Scholar]
- Bruder O, Wagner A, Lombardi M, Schwitter J, van Rossum A, Pilz G, Nothnagel D, Steen H, Petersen S, Nagel E. et al. European cardiovascular magnetic resonance (EuroCMR) registry - multi national results from 57 centers in 15 countries. J Cardiovasc Magn Reson. 2013;15:9. doi: 10.1186/1532-429X-15-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Andre F, Celik C, Abdel-Aty H, Santos MFB, Giannitsis E, Katus H, Steen H. Comparison of parameters for left ventricular volumes and function between echocardiography and cardiovascular magnetic resonance in a large group of cardiac patients. J Cardiovasc Magn Reson. 2013;15(suppl 1):E74. doi: 10.1186/1532-429X-15-S1-E74. [DOI] [Google Scholar]
- Joshi SB, Connelly KA, Jimenez-Juan L, Hansen M, Kirpalani A, Dorian P, Mangat I, Al-Hesayen A, Crean AM, Wright GA. et al. Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation. J Cardiovasc Magn Reson. 2012;14:69. doi: 10.1186/1532-429X-14-69. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wong TC, Piehler K, Puntil KS, Moguillansky D, Meier CG, Lacomis JM, Kellman P, Cook SC, Schwartzman DS, Simon MA. et al. Effectiveness of late gadolinium enhancement to improve outcomes prediction in patients referred for cardiovascular magnetic resonance after echocardiography. J Cardiovasc Magn Reson. 2013;15:6. doi: 10.1186/1532-429X-15-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Assomull RG, Shakespeare C, Kalra PR, Lloyd G, Gulati A, Strange J, Bradlow WM, Lyne J, Keegan J, Poole-Wilson P. et al. Role of cardiovascular magnetic resonance as a gatekeeper to invasive coronary angiography in patients presenting with heart failure of unknown etiology. Circulation. 2011;124:1351–60. doi: 10.1161/CIRCULATIONAHA.110.011346. [DOI] [PubMed] [Google Scholar]
- Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ. et al. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012;379:453–60. doi: 10.1016/S0140-6736(11)61335-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Greenwood JP, Walker S, Giardin F, McKenna C, Everett C, Nixon J, Brown J, Plein MS. Cost-effectiveness of magnetic resonance imaging in coronary heart disease: an economic evaluation using data from the CE-MARC study. J Cardiovasc Magn Reson. 2013;15(suppl 1):O7. doi: 10.1186/1532-429X-15-S1-O7. [DOI] [Google Scholar]
- Kelle S, Petrov G, Kern S, Fleck E, Wellnhofer E. Cost-effectiveness of dobutamine stress cardiac magnetic resonance imaging in stable coronary artery disease - a post-hoc analysis. J Cardiovasc Magn Reson. 2013;15(suppl 1):O8. doi: 10.1186/1532-429X-15-S1-W8. [DOI] [Google Scholar]
- Genders TS, Petersen SE, Pugliese F, Dastidar AG, Fleischmann KE, Nieman K, Hunink M. Stress myocardial perfusion cardiac magnetic resonance imaging vs. coronary CT angiography in the diagnostic work-up of patients with stable chest pain: comparative effectiveness and costs. J Cardiovasc Magn Reson. 2013;15(suppl 1):O9. [Google Scholar]
- Plein S, Herzog BA, Maredia N, Kidambi A, Motwani M, Uddin A, Ripley DP, Dickinson CJ, Brown J, Nixon J. et al. The ischaemic and scar burden measured by cardiac magnetic resonance imaging in patients with ischaemic coronary heart disease from the CE-MARC study. J Cardiovasc Magn Reson. 2013;15(suppl1):O105. [Google Scholar]
- Manka R, Gebker R, Wissmann L, Jogiya R, Motwani M, Frick M, Reinartz SD, Schnackenburg B, Nagel E, Plein S, Kozerke S. Multicenter evaluation of dynamic three-dimensional whole-heart myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve. J Cardiovasc Magn Reson. 2013;15(suppl 1):O103. doi: 10.1161/CIRCIMAGING.114.003061. [DOI] [PubMed] [Google Scholar]
- Parsai C, O’Hanlon R, Prasad SK, Mohiaddin RH. Diagnostic and prognostic value of cardiovascular magnetic resonance in non-ischaemic cardiomyopathies. J Cardiovasc Magn Reson. 2012;14:54. doi: 10.1186/1532-429X-14-54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Maron MS. Clinical utility of cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2012;14:13. doi: 10.1186/1532-429X-14-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ismail TF, Jabbour A, Gulati A, Mallorie A, Raza S, Cowling TE, Das B, Khwaja J, Wage R, Moon J. et al. Late gadolinium enhancement cardiovascular magnetic resonance for sudden cardiac death risk stratification in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2013;15(suppl 1):O67. doi: 10.1186/1532-429X-15-S1-O67. [DOI] [Google Scholar]
- Noureldin RA, Liu S, Nacif MS, Judge DP, Halushka MK, Abraham TP, Ho C, Bluemke DA. The diagnosis of hypertrophic cardiomyopathy by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2012;14:17. doi: 10.1186/1532-429X-14-17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Deva DP, Williams LK, Care M, Siminovitch KA, Moshonov H, Wintersperger BJ, Rakowski H, Crean AM. Incremental predictive value of deep crypts in the basal inferoseptum in the setting of hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2013;15(suppl 1):O33. doi: 10.1186/1532-429X-15-S1-O33. [DOI] [Google Scholar]
- Flett A, Maestrini V, Milliken D, Fontana M, Harb R, Sado D, Quarta G, Herrey AS, Elliott P, McKenna WJ, Moon J. A new variant of apical hypertrophic cardiomyopathy? T wave inversion and relative but not absolute apical left ventricular hypertrophy. J Cardiovasc Magn Reson. 2013;15(suppl 1):O36. doi: 10.1186/1532-429X-15-S1-O36. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sado DM, White SK, Piechnik SK, Banypersad SM, Treibel T, Captur G, Fontana M, Maestrini V, Flett AS, Robson MD. et al. Identification and assessment of anderson-fabry disease by cardiovascular magnetic resonance noncontrast myocardial t1 mapping. Circ Cardiovasc Imaging. 2013;6:392–8. doi: 10.1161/CIRCIMAGING.112.000070. [DOI] [PubMed] [Google Scholar]
- Simpson R, Keegan J, Firmin D. Efficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle. J Cardiovasc Magn Reson. 2013;15:34. doi: 10.1186/1532-429X-15-34. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Alexandre J, Saloux E, Dugue AE, Lebon A, Lemaitre A, Roule V, Labombarda F, Provost N, Gomes S, Scanu P, Milliez P. Scar extent evaluated by late gadolinium enhancement CMR: a powerful predictor of long term appropriate ICD therapy in patients with coronary artery disease. J Cardiovasc Magn Reson. 2013;15:12. doi: 10.1186/1532-429X-15-12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leyva F, Foley PW, Chalil S, Ratib K, Smith RE, Prinzen F, Auricchio A. Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:29. doi: 10.1186/1532-429X-13-29. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tse Z, Dumoulin C, Byrd I, Schweitzer J, Watkins R, Pauly KB, Kwong RY, Michaud GF, Stevenson W, Jolesz F, Schmidt EJ. Voltage-based electroanatomic mapping system for MR-guided cardiac electrophysiology: preliminary swine validations. J Cardiovasc Magn Reson. 2013;15(suppl 1):O88. doi: 10.1186/1532-429X-15-S1-O88. [DOI] [Google Scholar]
- Ramanan V, Celik H, Ghate S, Barry J, Ghugre NR, Leber V, Stainsby JA, Shmatukha A, Shurrab M, Crystal E, Wright G. Exploring intrinsic MR signal relaxation in acute RF ablation lesions using T2 mapping and IR-SSFP CINE imaging. J Cardiovasc Magn Reson. 2013;15(suppl 1):O87. doi: 10.1186/1532-429X-15-S1-O87. [DOI] [Google Scholar]
- Ainslie M, Miller CA, Brown B, Davidson N, Fox DJ, Schmitt M. Multiparametric CMR assessment of RV apical versus septal Pacing Study (MAPS) - preliminary acute hemodynamic findings. J Cardiovasc Magn Reson. 2013;15(suppl 1):O85. doi: 10.1186/1532-429X-15-S1-P85. [DOI] [Google Scholar]
- Muzzarelli S, Monney P, O’Brien K, Faletra F, Moccetti T, Vogt P, Schwitter J. Quantification of aortic valve regurgitation by phase-contrast magnetic resonance in patients with bicuspid aortic valve: where to measure the flow? J Cardiovasc Magn Reson. 2013;15(suppl 1):O37. doi: 10.1186/1532-429X-15-S1-O37. [DOI] [PubMed] [Google Scholar]
- Hart C, Gabbert DD, Voges I, Jerosch-Herold M, Andrade A, Pham M, Hansen T, Kramer H-H, Rickers C. New insights in the Fontan circulation: 4-dimensional respiratory- and ECG-triggered phase contrast magnetic resonance imaging. J Cardiovasc Magn Reson. 2013;15(suppl 1):O38. [Google Scholar]
- Markl M, Kilner PJ, Ebbers T. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:7. doi: 10.1186/1532-429X-13-7. [DOI] [PMC free article] [PubMed] [Google Scholar]