Table 2.
HFO Max, kPa | Threshold Pressure, kPa | Micturition Pressure, cmH2O | Baseline Pressure, cmH2O | Intercontraction Interval, s | Infused Volume, ml | Void Volume, ml | |
---|---|---|---|---|---|---|---|
Control | 2.3 ± 0.1 | 1.1 ± 0.1 | 3.1 ± 0.3 | 0.9 ± 0.1 | 480.8 ± 63.2 | 1.3 ± 0.2 | 1.3 ± 0.2 |
RVS | 2.3 ± 0.1 | 1.3 ± 0.1 | 2.9 ± 0.3 | 1.1 ± 0.1 | 203.9 ± 34.5* | 0.6 ± 0.1* | 0.6 ± 0.1* |
Mean bladder pressures and urodynamic parameters during conscious cystometry in male rats with or without RVS exposure. Values are means ± SE; n = 4/group. Threshold, micturition, baseline, and maximum high-frequency oscillation (HFO) pressures (kPa) during conscious cystometry for control and RVS-treated (7 days) rats are shown. Urodynamic parameters including intercontraction interval, infused volume, and void volume are also shown.
P ≤ 0.01 compared with controls.