Skip to main content
. Author manuscript; available in PMC: 2014 Mar 1.
Published in final edited form as: Circ Cardiovasc Imaging. 2013 Feb 11;6(2):195–201. doi: 10.1161/CIRCIMAGING.112.000132

Table 2.

99mTc-PYP SPECT data according to amyloid subtype

Category AL n=12 ATTRwt n=16 ATTRm n=17 P value
Semi-quantitative Visual Cardiac Score (%)
 Score <2 83 0 6 <0.0001
 Score ≥2 17 100 94
Quantitative Cardiac Score (cts)
 Heart absolute cts 21.8±2.7 27.7±0.9 30.4±3.6 0.10
 CL absolute cts 18.1±2.2 15.3±0.6 17.5±2.4 0.48
 H/CL ratio 1.21±0.04 1.84±0.06a 1.77±0.06a <0.0001
 Heart SD mean cts 5.4±0.3 6.5±0.2 6.7±0.5a 0.033
 CL SD mean cts 4.4±0.3 4.6±0.1 4.7±0.4 0.73
 Heart mean max cts/pix 40.2±3.7 52.0±1.8 54.2±4.8a 0.041
 CL mean max cts/pix 35.3±3.1 34.6±0.8 35.5±3.2 0.88
 Heart mean total cts/ROI 38,966±4,528 60,709±4,423a 58,346±4,764a 0.008
 CL mean total cts/ROI 32,132±3,591 33,904±1,724 35,285±3,140 0.72
 Heart mean area ROI (mm2) 4,672±417 5,356±302 5,303±336 0.36
 CL mean area ROI (mm2) 4,619±412 5,295±298 5,262±342 0.36

Continuous data are expressed as mean± SE, and categorical data are expressed as percentages.

Semi-quantitative and quantitative data were obtained 1 hour post 99mTc-PYP infusion.

Cts indicates counts; CL, contralateral; SD, standard deviation; Pix, pixels; ROI, region of interest.

a

P<0.05 by ANOVA with Bonferroni correction in comparison to AL.