Skip to main content
. 2013 Jul 27;69(Pt 8):891–894. doi: 10.1107/S1744309113017594

Table 1. Data-collection statistics and processing parameters for crystal forms A and B .

Values in parentheses are for the outermost resolution shell.

Crystal form A B
Beamline Rotating Cu anode CHESS F1
Detector R-AXIS IV++ ADSC Q270 CCD
Crystal-to-detector distance (mm) 150 150
Wavelength (Å) 1.518 0.9177
Temperature (K) 100 100
Resolution range (Å) 20.00–2.90 (3.00–2.90) 20.00–3.00 (3.11–3.00)
Space group P212121 P21212
Unit-cell parameters (Å) a = 81.9, b = 84.9, c = 124.2 a = 69.9, b = 77.7, c = 88.5
No. of measured reflections 19275 20439
No. of unique reflections 18118 7679
Multiplicity 2.7 (2.5) 2.7 (2.7)
Completeness (%) 95.0 (90.6) 76.1 (81.5)
Mean I/σ(I) 13.8 (3.2) 24.5 (12.3)
R merge (%) 11.8 (37.9) 7.6 (12.6)
V M3 Da−1) 2.23 2.48

R merge is defined as Inline graphic Inline graphic × 100, where I i(hkl) is the intensity of an individual reflection and 〈I(hkl)〉 is the average intensity for this reflection; the summation is over all intensities.