Skip to main content
. 2012 Dec 17;31(3):387–392. doi: 10.1200/JCO.2012.43.6691

Table 1.

Comparison of the Performance of PEB and ST Rules at Various Positivity Thresholds by Using Blood Samples Collected From 701 Control Participants

Screening-Rule Threshold
Actual Specificity (%) Total No. of FP Screens No. of Unique Women Experiencing an FP Screen
ST CA125 (U/mL) PEB z Score ST PEB
35 2.8 99.1 35 21 29
30 2.23 98.2 68 38 59
25 1.69 95.8 161 64 134
20 1.25 90.4 368 135 287

Abbreviations: FP, false-positive screen; PEB, parametric empirical Bayes; ST, single threshold.