Table 2.

Comparison of different tiers of public and private laboratories for biosafety engineered devices

Characteristics Class of laboratory Public laboratories
Private laboratories
OR 95% CI p
N1 No. with device (%) N2 No. with device (%)
Isolated micro lab Tertiary 4 4 (100.0) 2 2 (100.0)
Secondary 14 8 (57.1) 22 1 (4.5) 28.000 2.896–270.60 0.007
Primary 13 1 (7.7) 25 1 (4.0) 2.000 0.115–34.84 1.000
Leak-proof benches Tertiary 4 4 (100.0) 2 2 (100.0)
Secondary 14 14 (100.0) 22 13 (59.1) 20.407 1.079–385.86 0.006
Primary 13 6 (46.2) 25 18 (72.0) 3.000 0.740–12.130 0.163
Self-closing doors Tertiary 4 2 (50.0) 2 0 (0.0) 5.000 0.149–166.73 0.467
Secondary 14 5 (35.7) 22 4 (18.2) 2.500 0.530–11.656 0.267
Primary 13 0 (0.0) 25 1 (4.0) 0.604 0.023–15.911 1.000
Emergency exit Tertiary 4 1 (25.0) 2 0 (0.0) 2.143 0.059–77.605 1.000
Secondary 14 0 (0.0) 22 0 (0.0)
Primary 13 0 (0.0) 25 0 (0.0)
Hand washing sink Tertiary 4 4 (100.0) 2 2 (100.0)
Secondary 14 14 (100.0) 22 18 (81.8) 2.189 0.0987–48.536 1.000
Primary 13 9 (69.2) 25 7 (28.0) 5.786 1.335–25.074 0.019
Autoclave Tertiary 4 4 (100.0) 2 2 (100.0)
Secondary 14 14 (100.0) 22 15 (68.2) 14.032 0.733–208.54 0.028
Primary 13 13 (100.0) 25 18 (72.0) 10.940 0.5740–208.75 0.072
Fire extinguisher Tertiary 4 2 (50.0) 2 1 (50.0)
Secondary 14 4 (28.6) 22 1 (4.5) 8.400 0.827–85.276 0.064
Primary 13 0 (0.0) 25 1 (4.0) 0.605 0.023–15.911 1.000

CI, confidence interval; micro lab, microbiology laboratory; N1, number of public laboratories; N2, number of private laboratories; OR, odds ratio.