Characteristics of vWD samples subsequently tested by FCS.

Sample Antigen,
%
RCoF,
%
Factor
VIII, %
Multimer analysis Type
1 44 44 43 All multimers present in decreased amounts Type 1
2 43 28 38 All multimers present in decreased amounts Type 1
3 43 40 53 All multimers present in decreased amounts Type 1
4 45 42 73 All multimers present in decreased amounts Type 1
5 39 <20 42 All multimers present in decreased amounts Type 1/2M
6 13 <20 13 All multimers present in decreased amounts Type 1
7 43 40 63 All multimers present in decreased amounts Type 1
8 15 <20 48 All multimers present in decreased amounts Type 1
9 48 48 69 All multimers present in decreased amounts Type 1
10 37 26 26 All multimers present in decreased amounts Type 1
11 38 42 78 All multimers present in decreased amounts Type 1
12 32 25 37 All multimers present in decreased amounts Type 1
13 68 <20 14 No large or intermediate multimers Severe type 2A
14 31 <20 39 Absence of large multimers Type 2A
15 19 <20 39 Absence of large multimers Type 2A
16 50 <20 41 Absence of large multimers Acquired type 2
17 21 <20 31 Absence of large multimers Type 2A
18 17 <20 31 Absence of largest multimers Type 2A
19 41 <20 103 Absence of largest multimers Mild type 2A
20 77 35 65 Absence of large multimers Acquired Type 2
21 38 18 29 Absence of large multimers Type 2A
22 51 28 72 Absence of large multimers Acquired type 2?
23 31 <20 39 Absence of large multimers Type 2A
24 100 39 74 Absence of large multimers Type 2
25 146 62 132 Absence of large multimers Acquired type 2
26 188 121 112 Absence of largest multimers Mild acquired type 2