Number of CT examinations (NCT) and effective dose due to CT (ECT) in various countries

Country NCT /1000 population % of total number of X-ray examinations ECT/caput (mSv) % of total effective dose Reference
Switzerland (2008)
100
6
0.8
68
This work
France (2007)*
115
10
0.8
65
[7]
Germany (2008)
132
8
1.0
60
[8]
United Kingdom (2008)
53
7
0.3
67
[9]
The Netherlands (2008)
62
11
0.4
46
[10]
Norway (2008)**
194
29
0.9
80
[11]
Finland (2008)
60
8.3
0.3
58
[12]
USA (2006)
226
18
1.5
66
[13]
UNSCEAR (1997–2007) 129 8 0.9 47 [1]

* Therapeutic interventional procedures excluded.