Skip to main content
. Author manuscript; available in PMC: 2014 Sep 1.
Published in final edited form as: Ear Hear. 2013 Sep;34(5):562–574. doi: 10.1097/AUD.0b013e31828d2bd6

TABLE 2.

Performance on speech perception tests by children with cochlear implants

Linguistic Test Score Mean SD Range
Lexical Neighborhood Test (LNT) % correct words at 70 dB SPL 76.7 18.7 0–96
% correct words at 50 dB SPL 52.0 26.0 0–94
BKB Sentences in Noise SNR-50* (dB) 9.8 4.6 4–23
Non-word Repetition (CNRep) % total accuracy 26.9 21.7 0–85
% correct consonants 73.3 17.4 22–97
% correct number of syllables 84.7 16.1 20–100
% correct syllable stress 65.1 19.2 20–100
Indexical Test Score Mean SD Range

Emotion Identification % correct (chance=25%) 58.5 17.8 25–92
Emotion Discrimination % correct (chance=50%) 89.8 10.2 54–100
Talker Discrimination Across-Gender % correct (chance=50%) 89.0 12.6 53–100
Talker Discrimination Within-Female % correct (chance=50%) 65.4 10.6 41–84
*

SNR-50 = Signal-to-Noise Ratio at which listener achieves 50%-correct speech understanding