Figure 5.
When pressure is monitored in the stump of a segmental artery (SA) after sacrifice of all SAs, the collateral network pressure (CNP) falls initially, reaches its lowest point about 5 hours after SA sacrifice, and recovers reliably between 72 hours to 5 days even in pigs that subsequently exhibit signs of functional spinal cord injury (8)